Mitsubishi Electronics 882.00273.00 Manual Do Utilizador

Página de 101
Feeder Clean Out 
Any feeder in the Slide Gate/Auger blending system can be emptied and refilled with a 
different material. To do a feeder clean out, the operator has to press the “Clean Out” icon 
key from the recipe screen (the first screen that appears on power up).   
This screen will allow you to Open or Close the Feeder, Weigh Hopper, Mixer Knife Gate, 
Empty the Entire Blender, Start or Stop the Mixer Motor, Test the Alarm Output, Find out the 
Mixer Proximity Status and monitor the Current Hopper Weight. 
Figure 47: Typical Manual Control Operator Screen 
 
Empty Entire 
Blender 
Warning Message 
Current Hopper 
Weight 
Go back to Setup 
Directory 
Test Alarm 
Output 
Open or Close 
Weigh Hopper 
Start or Stop Mixer 
Motor 
Open or Close 
Mixer Knife Gate 
Low Level Prox 
Status 
Open or Close 
Feeder 
The dump valve opens as soon as the “Press to Open Feeder” key is pressed. This easy feeder 
clean out option also serves as a means for emptying a batch that is held in the weigh hopper 
if the “Press to Open Weigh Hopper” key is pressed when the blender is stopped. To 
open/close feeder numbers 2, 3, 4, 5 & 6 press the number next to “Press to Open Feeder” to 
select the feeder you desire to empty and the “Press to Close Feeder” key to close the dump 
valve.  Touch the “Done” key to return to the recipe menu. After entering a recipe, the 
operator will restart the blending system, putting it back in normal operation. 
Note:   Before starting Slide Gate/Auger blending systems, each ingredient 
hopper in the current recipe must contain material!  Virgin material 
must be loaded in hopper #1 and hopper #3 should only be used for 
regrind!! 
Once the operator initiates the run mode of operation, the blending system controller will 
begin monitoring the mixer high-level switch. Nothing will happen until the mixer high-level 
switch is uncovered. This tells the controller that the mixing chamber is capable of holding 
another batch of material. 
Once the mixer high-level switch is uncovered, and the weigh hopper has dumped, the system 
will meter the ingredients from the supply hoppers, through the metering units, into the weigh 
hopper. Each component will be metered individually to allow accurate weighing of the 
material. 
Each component is metered in the order specified by the “Metering Order” setup. See the 
Installation & Setup chapter for further details. 
Once the final ingredient specified in the recipe has been metered into the weigh hopper, the 
controller will take a final weight reading of the weigh hopper. This will start the “Dump 
BF1-615.3 
Chapter 4: 3BOperation 
59 of 101