Cornelius 3 Manual Do Utilizador

Página de 74
                               
Viper Service Manual
© 2010, IMI Cornelius Inc.
- 31 -
Publication Number: 621360041TBSER
To move between one set of barrel parameters to the next, press the Right or 
Left arrow keys. This moves the highlight to the first entry of the second barrel, 
etc.
Totals Menu
The Totals menu (Figure 23) shows the cumulative run time of the system, a 
component of the system or an error. Some individual items may be reset, 
where available, by highlighting the item and pressing the RESET button. The 
RESET button is only displayed for items that may be reset, such as hours since 
the motor seal was changed or the number of compressor cycles. Pressing the 
BACK button returns to the Choose menu and saves the changes. The descrip-
tion of each item in the Totals list is shown in Table 26.
To move between one set of barrel parameters and the next, press the Right or 
Left arrow keys. This highlights the first entry of the second barrel, etc.
Figure 23. Totals Screen
PRODUCT SOL #1
This selection opens and closes the product solenoids and valves 
for barrel 1
CO2 VALVE #1
This selection opens and closes the CO
2
 solenoic and valve for 
barrel 1
LLS VALVE #1
This selection opens and closes the Liquid Line solenoid and 
valve for barrel 1
BRL MOTOR #1
This selection turns the barrel 1 motor on and off
Table 25
Display
Description
Table 26
Display
Value
Description
POWER ON
HHHHH:MM
Shows how long the machine has been powered 
up
SLEEP
HHHHH:MM
Shows how long the machine has been in sleep 
mode
SYSTEM ERROR
HHHHH:MM
Shows how long the machine has had a system 
error
COMP RUN #1
HHHHH:MM
Shows how long the compressor has been run-
ning since the last reset
COMP CYCLES #1
########
Shows the number of compressor cycles since 
the last reset
BARREL REFG #1
HHHHH:MM
Shows how long the barrel has been in refrigera-
tion mode
MOTOR ON #1
HHHHH:MM
Shows how long the motor has been running on a 
specific barrel
MOTOR SEAL #1
HHHHH:MM
Shows how long it has been since the motor seal 
was inserted on a specific barrel
TOTALS
12:51P
MAR 04
POWER ON            00079:34
SLEEP                    00034:21
BACK
SYSTEM ERROR   00003:45
COMP RUN      #1  00006:53
COMP CYCLES #1 0000012
BARREL REFG #1  00006:54