Cornelius 3 Manual Do Utilizador

Página de 74
                             
Viper Service Manual
© 2010, IMI Cornelius Inc.
- 51 -
Publication Number: 621360041TBSER
Installing a New Seal
Perform the procedure in Table 43, Figure 41 and Figure 42 to replace the barrel 
seal with a new seal. When installing a new seal, 
NEVER use oil or silicon 
based lubricants. This can cause the new seal to rotate and 
LEAK!
Figure 41. View of Motor Shaft with Spacer on Shaft
Table 43
Step
Action
1
Remove the old seal and the spacer (see Table 42).
2
Remove the new seal from its packaging.
3
Clean the spacer.
4
Slide the spacer (with slots toward the motor housing) over the motor shaft.
5
Lubricate the inside of the seal using Dow Corning 111 Lubricant and Sealant. 
(Note, Do not lubricate the static side(outer portion) of the seal. This could 
cause the seal to rotate in the bore and leak.)
6
Carefully slide the seal over the motor shaft and press it firmly until is fully 
seated against the spacer and the seal cannot be pushed any further.
7
Run your finger around the perimeter of the seal to insure it is flush against the 
back of the barrel.
8
Reinstall the blade assembly. Rotate the assembly while inserting it to insure 
that it is fully seated on the motor shaft. (Figure 30)
9
Lubricate the faceplate o-ring.
10
Re-install the faceplate and replace the four (4) mounting nuts. Hand tighten
the nuts until the faceplate makes contact with the gasket, then use a wrench
to tighten the nuts an additional 1/4 turn. Be careful not to overtighten the nuts
or cracking of the faceplate may result.
11
Clean the drip tray and tube using warm water.
12
Perform the seal leak test in Table 44.
Motor Shaft
Spacer
(Note Orientation)