Fujitsu MAT3073NC/NP Manual Do Utilizador

Página de 130
 
7-4 
C141-E201 
7.2.2 
Sense data (3-0C-03), (4-40-xx), and (4-C4-xx) 
 
Sense data (3-0C-03), (4-40-xx), and (4-C4-xx) indicate one of the following: 
• 
A target sector could not be detected using the sector counter. 
• 
A seek process overran the specified time. 
• 
A write to a disk terminated abnormally. 
• 
An error occurred in power-on self-diagnosis. 
• 
A drive error occurred. 
 
The symptoms above are generally caused by an error in a PCA or DE. 
 
For details of the sense data above, refer to the SCSI Logical Interface Specifications. 
7.2.3 
Sense data  (1-1x-xx), (3-1x-xx) and (E-1D-00):  Disk read error 
 
If sense data (1-1x-xx), (3-1x-xx) or (E-1D-00) occurs frequently in a specific block of a disk, 
there is disk damage that was not recorded in the media defect list.  In this case, assign an alternate 
block to the error-detected block using a REASSIGN BLOCKS command.  For an explanation of 
the REASSIGN BLOCKS command, refer to the SCSI Logical Interface Specifications. 
 
If this error occurs in different blocks, a PCA or DE is faulty. 
 
For details of the above sense data, refer to the SCSI Logical Interface Specifications. 
7.2.4 
Sense data  (5-2x-xx), (5-3D-00), (5-90-00), (B-44-xx), (B-47-xx), (B-49-00), (B-4D-xx) and  
(B-4E-00):  SCSI interface error 
 
Sense data (5-2x-xx), (5-3D-00), (5-90-00), (B-44-xx), (B-47-xx), (B-49-00), (B-4D-xx) and  
(B-4E-00) indicates one of the following symptoms: 
• 
An invalid or unsupported command was issued, or invalid or unsupported parameters were 
specified. 
• 
A SCSI interface error occurred. 
• 
A hardware error occurred inside IDD. 
• 
A parity error occurred in the SCSI bus. 
 
If this error occurs, a PCA or the SCSI interface cable is faulty. 
 
For details of the above sense data, refer to the SCSI Logical Interface Specifications.