5.3.2  
Each mode setting 
(1) 
Setting terminator power supply 
 
Refer to Table 5.2 for controlling the supply of power from the drive to the SCSI terminator power 
source (TERMPOW).  
 
For information on NP model, refer to Figures 5.2 and 5.3. 
Table 5.2 
Setting SCSI terminator power supply (NP model) 
Supply on/off of SCSI terminator power from 
IDD 
CN2 23-24 
Supply off 
Open 
Supply on 
Short (*1) 
*1.  Set at factory shipment. 
 
For NC model, the function of the terminator power supply setting is not supported. 
(2) 
Motor start mode 
 
Set how to control the starting of the IDD spindle motor according to Table 5.3.  This setting only 
determines the operation mode when the power supply is turned on or the microcode is 
downloaded.  In both modes, stopping or restarting the spindle motor can be controlled by 
specifying the START/STOP UNIT command. 
Table 5.3 
Motor start mode setting  
NC model (*3) 
NP model 
Start timing of the spindle motor 
CN1 38 
CN1 78 
CN2 11-12 
Starting of the motor is controlled with the 
START/STOP UNIT command. 
Short 
Open or Short 
Open 
The motor is started immediately after the 
power supply is turned on or after the 
microcode is downloaded. 
Open Open Short (*1) 
The motor is started after the elapse of a delay 
time that is based on the SCSI ID.  The delay 
time is provided immediately after the power 
supply is turned on or after the microprogram is 
downloaded. 
Open Short  (*2) 
*1.  Set at factory shipment. 
*2.  For NP model, delay starting of spindle motor is supported by the CHANGE  DEFINITION 
command only. 
*3.  To set the setting terminals on NC models to short, apply voltage ranging between-0.3 V and 
0.8 V to the setting terminals externally.  To set the setting terminals on NC models to open, 
apply voltage ranging between 2.0 V and 5.5 V to the setting terminals from an external source. 
 
Refer to Chapter 3 of the SCSI Logical Interface Specifications for details of the START/STOP 