GAS CONNECTION
3) Locate the center point where the flue will
pass through the chimney above the appli-
ance. Move the appliance into the exact
location where it is to be installed. Ensure
that the Insert is level.
ance. Move the appliance into the exact
location where it is to be installed. Ensure
that the Insert is level.
4) The installer must provide a valve with a
plugged tapping, accessible for test gauge
connection, immediately upstream of the
gas supply connection to the appliance.
connection, immediately upstream of the
gas supply connection to the appliance.
CAUTION: If the glass is removed or
opened for servicing, it must be re-
placed and closed prior to operating the
appliance. The glass must be fixed in the
door when operating.
opened for servicing, it must be re-
placed and closed prior to operating the
appliance. The glass must be fixed in the
door when operating.
GAS CONNECTION WARNING:
Only persons licensed to work with
gas piping may make the neces-
sary gas connections to this appli-
ance.
Only persons licensed to work with
gas piping may make the neces-
sary gas connections to this appli-
ance.
1) If the appliance is to be installed into an
existing chimney system, thoroughly clean
the masonry or factory built fireplace.
the masonry or factory built fireplace.
2) The gas connection is 12" BSP.
SPECIFICATIONS
INSTALLATION
NOTE: Mantel clearances for Installation
into a Zero Clearance Kit are differ-
ent. Please refer to the Zero Clear-
ance Kit Manual for details.
ent. Please refer to the Zero Clear-
ance Kit Manual for details.
Mantel Clearances with
Bay and Flush Louvres in
Masonry Installation
MINIMUM FIREPLACE
DIMENSIONS
The minimum fireplace dimensions for the Re-
gency gas space heater are shown in the
following diagrams:
gency gas space heater are shown in the
following diagrams:
Note: A non-combustible mantel may
be installed at a lower height if the
framing is made of metal studs
covered with a non-combustible
board.
framing is made of metal studs
covered with a non-combustible
board.
MINIMUM
CLEARANCES TO
COMBUSTIBLES
The minimum fireplace clearances for the Re-
gency gas space heater are shown in the
following diagrams:
gency gas space heater are shown in the
following diagrams:
From Unit
Sides
A 255 mm
Ceiling
B 1205 mm
Mantle
C see Mantel
Clearances
From Surround
(660 mm x 1016 mm)
(660 mm x 1016 mm)
Max. Mantle Depth
G 305 mm
Hearth Height
H 0 mm
Hearth Depth
I
405 mm
Hearth Width
J 1015 mm
Min. Alcove Width
K 1220 mm
Max. Alcove Depth
L 915 mm
NG
LPG
INJECTOR
#37
#52
SIZE
2.65mm
1.6mm
INPUT
Min. 17 mj/h
Min. 17 mj/h
RATING
Max. 31 mj/h
Max. 31 mj/h
MANIFOLD
PRESSURE Max. 0.9 kPa
Max. 2.59 kPa