Ariston G.C.N.:47-116-65 (24 kW) Manual Do Utilizador

Página de 72
19
installation
Warning
The exhaust gas ducts must not be in contact with or close 
to infl ammable material and must not pass through building 
structures or walls made of infl ammable material.
When replacing an old appliance, the fl ue system must be 
changed.
 
Important
Ensure that the fl ue is not blocked.
Ensure that the fl ue is supported and assembled in accordance 
with these instructions.
150 mm
118
* Min slope: 1˚ 
                1˚= 17.5mm per metre
150 mm 
* pente 
Installation without extension
Installation with extension
Level
Level
 Fitting the Coaxial Flue   (Ø 60 / 100 Horizontal)
 Contents:
1x Silicone O-Ring (60mm)
1x Elbow (90°)
2x Wall Seals (Internal & External)
1x Flue Pipe including Terminal (1 metre - 60/100)
2x Flue Clamps
4x Screws
2x Seals
Once the boiler has been positioned on the wall, fi t the rubber 
fl ue seal into the internal fl ue turret (see diagram opposite), 
Insert the elbow into the socket and rotate to the required 
position. note: It is possible to rotate the elbow 360° on its vertical 
axis.
Using the fl ue clamp, seals and screws supplied (Fig 4) secure the 
elbow to the boiler.
The 1 metre horizontal fl ue kit (3318073) supplied is suitable for 
an exact X dimension of 753mm.
 
Measure the distance from the face of the external wall to the face 
of the fl ue elbow (X - Fig 2), this fi gure must now be subtracted 
from 753mm, you now have the total amount to be cut from the 
plain end of the fl ue.
Draw a circle around the outer fl ue and cut the fl ue to the required 
length taking care not to cut the inner fl ue, next cut the inner 
fl ue ensuring that the length between the inner and outer fl ue is 
maintained. (Fig 4). 
e.g.
 
X = 555mm 
 
753-555 = 198mm (Length to be cut from the plain end of the 
fl ue).
Once cut to the required length, ensure that the fl ue is free from 
burrs and reassemble the fl ue. If fi tting the fl ue from inside of 
the building attach the outer wall seal to the fl ue terminal and 
push the fl ue through the hole, once the wall seal has passed 
through the hole, pull the fl ue back until the seal is fl ush with the 
wall.  Alternatively, the fl ue can be installed from outside of the 
building, the outer seal being fi tted last.
Should the fl ue require extending, the fl ue connections are push 
fi t, however, one fl ue bracket should be used to secure each metre 
of fl ue.
Note: See table for maximum and minimum fl ue runs.
slope
Fig. 3
Note: A Plume management kit is available for 60/100 
horizontal termination. Instructions for installation are 
supplied with the Plume management kit.