installation
Fitting instructions for:
•  Internal mechanical time clock
•  Internal RF receiver for Ariston programmable 
   room thermostat
These instructions to be used in conjunction with the appliance 
installation instructions. Ensure the appliance is electrically 
isolated before working on the appliance.
Remove the outer casing, and remove the front control panel by 
removing the 2 securing screws.
Remove the clock blanking plate (or existing clock if fi tting the RF 
receiver in a product with an existing mechanical clock) from the 
front control panel of the boiler.
Using the 4 securing screws supplied with the clock accessory, 
secure the clock/RF receiver into position, ensuring the accessory 
is oriented correctly.
Connect the wires to the clock accessory using the spade 
connectors (see fi g. 1 for wiring confi guration)
  
Fig. 1
Reassemble appliance, turn on electrical supply and operate 
accessory using instructions supplied.
1 Red 
Wire
Double Black wire
3 Black 
wire
4 Spare 
terminal
5 Blue 
wire 
 
Rear view of 
Time clock
Accessory