commissioning
Ignition procedure
Press the ON/OFF button on the control panel to switch on the 
boiler. The display shows:
● the operating mode: 
winter
summer
   
Only heating - CLAS HE EVO SYSTEM
● The fi gures indicate:
-   the fl ow temperature when no heating requests have been made 
-   the fl ow temperature in central heating mode 
-   the temperature of the hot water set in domestic hot water
The carrying out of certain functions is shown:
Deaeration cycle started
Centrl Heating Post-circulation
D.H.W. circuit Post-circulation
Electricity supply 
 -  Check that the voltage and frequency of the electricity supply 
correspond to the data shown on the boiler data plate; 
 -  Make sure that the earthing connection is effi
  cient. 
First ignition 
1.
 Make sure that: 
-  The gas valve is closed;
 -  The electrical connection has been properly carried out. 
Make sure that, in any case, the green/yellow earthing wire is 
connected to an effi
  cient earthing system;
 -  Use a screwdriver to lift the cap on 
the automatic air relief valve;
 -  Switch on the boiler (by pressing 
the ON/OFF button) and use the 
M
ODE
 button to select the standby 
mode, where no hot water or 
heating requests are made. 
-  Start the deaeration cycle by 
pressing ESC for 5 seconds
 
The boiler will start a deaeration 
cycle lasting about 7 minutes 
(See below). If you need to stop it 
press E
SC
, alternatively it is possible to manually vent the heat 
exchanger.
-  At the end, check that the system is completely deaerated 
and, if not, repeat the procedure. 
-   Bleed the air from the radiators;
The exhaust duct for combustion products should be suitable 
and free from any obstructions;
-   Any necessary ventilation inlets in the room should be open 
(type B installation).
Check whether the condense trap contains water; if not, it 
must be refi lled.
 
N.B.: if the boiler will not be used for long periods, the 
trap should be fi lled before the boiler is started up again. 
It is dangerous not to refi ll the siphon as fumes may be 
released into the environment.
2.  Open the gas cock and check the connection seals, including 
the boiler connection joints, making sure that the meter does 
not detect any passage of gas. Eliminate any leaks.
3.  Start the boiler by selecting the heating or domestic hot water 
operation using the M
ODE
 button.
Description of Function
Deaeration cycle
During the fi lling stage or if there is excess air in the system, the 
deaeration cycle can be activated by holding the OK button for 5 
seconds. The boiler will start a cycle which lasts approximately 7 
minutes. When this is complete the menu screen will be restored. 
The cycle may either be repeated, if necessary, or stopped by 
pressing OK. Press the OK button until the normal display screen is 
restored.   I
F
 
THE
 
CYCLE
 
IS
 
STOPPED
 
BE
 
SURE
 
TO
 
MANUALLY
 
VENT
 
THE
 
APPLIANCE
.