Ariston G.C.N.:47-116-65 (24 kW) Manual Do Utilizador

Página de 72
40
settings - adjustment - problem identifi cation menus
Accessing the settings - adjustment - problem identifi cation 
menus
The boiler can be used to manage the heating and domestic hot 
water production system in its entirety.
Navigation within the menus enables the boiler system + 
connected peripheral units to be customised, optimising 
operation for maximum comfort and maximum saving. It also 
provides important information relating to the effi
  cient operation 
of the boiler.
Before access to the menus, the display show some “quick 
settings” to have direct access to the parameters.
To see all available parameters and menu access to view FULL 
MENU.
GAS - Direct access to the parameters:
220 - 231- 232- 233 - 234 - 270
SET - Direct access to the parameters:
220 - 231- 223 - 245 - 246
PCB - Direct access to the parameters:
220 - 228 - 229 - 231- 232- 233 - 234 - 247 - 250 - 253
VIS - Direct access to the parameters:
821 - 822 - 824 - 825 - 827 - 830 - 831 - 832 - 833- 840 - 835
ZONE - Direct access to the parameters:
402 - 502 - 602 - 420 - 520 - 620 -434 - 534 - 634 - 830
FULL MENU  - see table on following pages
0
NETWORK
0
4
User Interface
2
Boiler Parameter
2
0
General setting
2
2
General setting
2
3
C.H. Parameters - Part 1
2
4
C.H. Parameters - Part 2
2
5
Domestic Hot Water
2
6
Boiler manual settings
2
7
Test & Utilities
2
8
Menù 2 Reset to factory setting
4
Zone 1 Parameters
4
0
Set-point Zone1
4
2
Zone 1 Setting
4
3
Diagnostics
5
Parametri Zona 2
5
0
Set-point Zone2
5
2
Zone 2 Setting
5
3
Diagnostics
6
Parametri Zona 3
6
0
Set-point Zone3
6
2
Zone 3 Setting
6
3
Diagnostics
8
Service Parameter
8
1
Statistics
8
2
Boiler
8
3
Boiler Temperature
8
4
Solar & Storage
8
5
Service
8
6
Error History
The parameters relating to each individual menu are listed in the 
following pages.
The various parameters can be accessed and modifi ed using the OK 
button and the encoder (see fi g. below). 
The description of the menus and of each individual parameter will be 
shown on the display.
6. E
SC
 button 
7. “encoder” 
programming knob 
8. O
K
 button  programming key
6
7
8
To access the Menus, proceed as follows (for example: “231
231”:
1.   Simultaneously  press  the
 ESC    button and OK button for 5 
seconds; the display show CODE and 222. 
 
Caution! The menus reserved for qualifi ed technicians may only 
be accessed after setting the access code.
2.  Turn the encoder 
 in a clockwise direction to select code 234
3.  Press the OK button; the display show the fi rst “quick setting” GAS
4.  Turn the encoder 
 to select  MENU;
5.   Press the OK button; the dispaly show the menu 
0
.
6.   Turn the encoder 
 in a clockwise direction to select the menu 
2
7.  Press the OK button to access to the menu. The display show the 
sub-menu 
20
8.
 
Turn the encoder 
 to select a sub menu 
23
9.   Press the OK button to access the sub menu parameters; the 
display show 
230
10.  Turn the encoder 
 to select a parameter 
231
 
11. Press the OK button to access the parameter; the display will 
indicate the value, e.g “
70
”.
 
Note: The parameter value will be displayed for 20 seconds, then 
will begin to fl ash in alternation with the parameter, e.g. “
70
  > 
231
 “.
12.  Turn the encoder 
 to select the new value, e.g. “
75
”.
13.  Press OK button to save the change or press E
SC
 to exit without 
saving.
To exit, press the E
SC
 button until the normal display screen is restored.
For menus which do not require the access code, it is possible to pass 
directly from the menu to the sub menu.