Settlement of outdoor unit
Anchor the outdoor unit with
a bolt and nut 10 or 8 tightly
and horizontally on a concrete
or rigid mount.
MODEL
A (mm)
B (mm)
Drain joint installation
Fit the seal into the drain elbow, then 
insert the drain joint into the base pan 
hole of outdoor unit, rotate 90 to 
securely assemble them.
Connecting the drain joint with an 
extension drain hose (Locally 
purchased), in case of the water 
draining off the outdoor unit during the 
heating mode.
17 electrolux outdoor unit installation
Flaring work
Main cause for refrigerant leakage is 
due to defect in the flaring work.
Carry out correct flaring work using 
the following procedure:
1. Cut the pipes and the cable.
A) Use the piping kit accessory or 
pipes purchased locally.
B) Measure the distance between the 
indoor and the outdoor unit.
C) Cut the pipes a little longer than 
the measured distance.
D) Cut the cable 1.5m longer than the 
pipe length.
2. Burr removal
A) Completely remove all burrs from 
the cut cross section of pipe/tube.
B) Put the end of the copper 
tube/pipe in a downward direction as 
you remove burrs in order to avoid 
dropping burrs into the tubing.
3. Putting nut on
A) Remove flare nuts attached to 
indoor and outdoor unit, then put 
them on pipe/tube having completed 
burr removal.(not possible to put them 
on after flaring work)
Refrigerant pipe connection
refrigerant pipe connection
 electrolux 18
Air inlet
Air
inlet
Air outlet
A
B
 
Base pan hole
of outdoor unit
Seal
Drain joint
Seal
Drain pipe
+
=
Pipe
Correct
Wrong
Oblique Roughness Burr
Pipe
Reamer
Point
down
Flare nut
Cooper tube
458
460
549
530
523
560
590
250
276
276
290
340
335
333
700x535x235
685x430x260
780x540x250
760x590x285
820x600x345
845x695x335
895x860x330