Monessen Hearth CDVR33N/PV7 Manual Do Utilizador

Página de 60
74D3000
3
BLDV7 Series Gas Fireplace
FIrepLaCe InStaLLatIon 
A listed manual shutoff valve must be installed upstream 
of the appliance. Union tee and plugged 1/8" NPT pres-
sure  tapping  point  should  be  installed  upstream  of the 
appliance. Figure 31
IMPORTANT: Install main gas valve (equipment shutoff 
valve) in an accessible location. The main gas valve is for 
turning on or shutting off the gas to the fireplace. 
Check  your  building  codes  for  any  special  requirements  for  locating  equipment  shutoff  valve  to 
fireplaces.
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. 
Excess sealant in pipe could result in clogged burner system valve.
We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 31. Locate 
sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel 
supply and burner system. Locate sediment trap/drip leg where trapped matter is not likely to freeze. 
A sediment trap collects moisture and contaminants and keeps them from going into the burner 
system gas controls. If sediment trap/drip leg is not installed or is installed wrong, burner system 
may not run properly. 
note: The gas line connection may be made using 1/" rigid tubing or an approved flex connector. 
Since some municipalities have additional local codes it is always best to consult your local authorities 
and the current edition of the National Fuel Gas Code ANSI.Z3.1, NFPA54. In Canada CSA-B149 
(1 or ) Installation Code. 
w
arn
In
G
only  persons  licensed  to  work  with  gas 
piping  may  make  the  necessary  gas 
connections to this appliance.
C
aut
Ion
a  manual  shutoff  valve  must  be  installed 
upstream  of  the  appliance.  union  tee  and 
plugged  1/8”  npt  pressure  tapping  point 
should be installed upstream of the appliance. 
Figure 31
C
aut
Ion
use pipe joint sealant that is resistant to liquid 
petroleum (Lp) gas.
3" Minimum
FP1978
gas connection
Pipe Nipple
Cap
Figure 31 - 
Gas Connection 
Tee Joint
Approved Flexible 
Gas Line 
CSA Design-Certified Equipment Shutoff Valve 
with 1/8" NPT Tap*
Sediment Trap/Drip Leg 
natural Gas
From Gas Meter 
(4.5" w.c. to 10.5" w.c. Pressure)
propane/Lp
From External Regulator 
(11" w.c. to 13" w.c. Pressure)