Runco cl-410 Guia Do Utilizador

Página de 72
Runco CL-410 and CL-420 Owner’s Operating Manual
49 
5.5 
Lamp Cautions
This projector uses a pressurized mercury lamp. A loud sound may 
indicate lamp failure. Lamp failure is caused by excessive shock, 
improper cooling, surface scratches or deterioration of the lamp due 
to usage. The period of time up to failure largely varies depending on 
the individual lamp and the condition and the frequency of use. It is 
important to note that failure can often result in the bulb cracking.
When the lamp replacement indicator and on-screen display icon are 
illuminated or are flashing, replace the lamp with a new one 
immediately, even if the lamp appears to be operating normally.
If the lamp breaks, glass particles may spread inside the lamp cage 
or gas contained in the lamp may be vented into the room from the 
exhaust vent. As the gas in this lamp contains mercury, ventilate the 
room well if the lamp breaks and avoid all exposure to the released 
gas. In case of exposure to the gas, consult a doctor as soon as 
possible.
If the lamp breaks, there is also a possibility that glass particles may 
spread inside the projector. If this happens, contact your nearest 
Authorized Dealer to remove the damaged lamp and ensure safe 
operation.
Do not remove the lamp unit immediately after turning off the 
projector. Touching a hot lamp can cause burns or injury. Wait at 
least one hour after the disconnecting the power cord to allow the 
surface of the lamp unit to fully cool before removing.
Caution