CUG (Closer User Group): This supplementary service is used to define a closed
group of users and create a private virtual network, in which only the members can
communicate. Set the Closed User Group (CUG) value between:
group of users and create a private virtual network, in which only the members can
communicate. Set the Closed User Group (CUG) value between:
• No request: CUG service is not requested
• Inside: to call a member of the CUG
• Outside: to call a user that doesn't belong to any CUG
• User (x): to call a user that belongs to a different CUG, enter the CUG
• Inside: to call a member of the CUG
• Outside: to call a user that doesn't belong to any CUG
• User (x): to call a user that belongs to a different CUG, enter the CUG
identification
Protocol: choose your local ISDN protocol.
Set the “LEASED LINE” value to perform tests without signalling
protocol over the D channel, i.e. Unframed BER. Use the
“OTHER” parameter to capture signalling protocols not directly
supported by the instrument in Monitor mode. See chapter 7.
protocol over the D channel, i.e. Unframed BER. Use the
“OTHER” parameter to capture signalling protocols not directly
supported by the instrument in Monitor mode. See chapter 7.
Protocol type: Define the operation mode of the active protocol between Master and
Slave. When you select the instrument operation mode, i.e. TE or NT, the “Protocol
type” parameter will be automatically set with the typical value for the configuration.
Slave. When you select the instrument operation mode, i.e. TE or NT, the “Protocol
type” parameter will be automatically set with the typical value for the configuration.
This parameter only should be changed in case of special use of
the instrument.
the instrument.
CDN(type/plan): choose ‘Type of number’ and ‘Numbering plan’ combination for the
Called Party Number.
Called Party Number.
CGN(type/plan): choose ‘Type of number’ and ‘Numbering plan’ combination for the
Calling Party Number.
Calling Party Number.
Add 100
Ωterminations: choose if you want to add a 100 Ω termination. You can
use this option if the line at this point is not terminated correctly. The default value is
NO.
NO.
Calls accept: select the incoming calls that will be automatically answered.
3.3.2. POTS access
The following parameters can be defined in the COMMON
SETUP for the POTS access termination.
SETUP for the POTS access termination.
Select the line impedance value according with local loop impedance.
CHAPTER 3 - PERFORMING A MANUAL TEST
35