INSTALLATION IN TO A FACTORY BUILT 
(METAL) FIREPLACE 
        (Refer to figure 20) 
 
When installing into a factory built fireplace, the firebox 
must accept the insert without modification other than 
removing bolted or screwed together pieces such as 
smoke shelf/deflectors, ash lips, screen or door tracks 
and damper assemblies. These items must be 
reinstalled to restore the fireplace to its original 
operating condition if the insert is removed and not 
replaced. The removal of any part must not alter the 
integrity of the listed fireplace in any way. In zero-
clearance fireplace installations, when the fireplace 
opening is above the floor or raised hearth, the 
adjustable “Breckwell P22 Z-C Legs” can be used to 
bridge the gap between the hearth and stove bottom. 
Refer to figure 14. 
The factory built fireplace must be listed per UL 127. 
Installation must include a full height listed chimney 
liner meeting type HT requirements (2100?   F) per 
1777 (U.S.). The liner must be securely attached to the 
insert flue collar and the chimney top. The damper area 
must be sealed to prevent room air passage to 
chimney cavity.  
 
Alteration of the fireplace in any manner is not 
permitted except with the following exceptions: 
  External trim pieces, which do not affect the 
operation of the fireplace, may be removed proving 
they can be stored on or within, the fireplace for re-
assembly if the insert is removed. 
  The fireplace damper may be removed to install the 
chimney liner. 
Circulating air chambers, louvers or cooling air inlet or 
outlet ports (i.e. in a steel fireplace liner or metal heat 
circulator) shall not be blocked. 
Means must be provided for removal of the insert to 
clean the chimney flue. 
A permanent metal warning label must be attached to 
the back wall of the fireplace opening stating the 
following: 
  “This fireplace has been altered to accommodate a 
fireplace insert and should be inspected by a 
qualified person prior to re-use as a conventional 
fireplace.” 
  This label is available upon request. 
 
Final approval is contingent on the authority 
having jurisdiction. 
 
ELECTRICAL INSTALLATION 
 
This stove is provided with a 6-foot grounded electrical 
cord extending from the rear of the stove. We 
recommend connecting to a good quality surge 
protector that is plugged into a standard three-prong, 
120V, 60hz electrical outlet. Voltage variations can lead 
to serious performance problems. The Breckwell 
electrical system is designed for 120V AC with no more 
than 5% variation. Breckwell cannot accept 
responsibility for poor performance or damage due to 
inadequate voltage. If connected to an older, two-prong 
outlet, a separate ground wire should be run to a 
proper ground (refer this to a qualified technician). 
Always route the electrical cord so that it will not come 
in contact with any hot part of the stove. 
 
 
 
 
 
 
SPECIAL MOBILE HOME REQUIREMENTS 
 
WARNING: DO NOT INSTALL IN A SLEEPING ROOM. 
 
For installation in a mobile home, an outside source of combustion air must be 
used (see “COMBUSTION AIR SUPPLY”). 
 
The P22 must be grounded to the steel chassis of the home with 8 Ga. copper 
wire using a serrated or star washer to penetrate paint or protective coating to 
ensure grounding. 
 
The P22 must be securely fastened to the floor of the mobile home. 
 
Refer to “VENTING” for proper exhaust configurations. 
 
CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, 
WALL AND CEILING/ROOF MUST BE MAINTAINED. 