Whirlpool wgd9600ta Manual Do Utilizador

Página de 32
10
Dryer gas pipe
The gas pipe that comes out through the rear of your dryer has a 
3
/
8
" male pipe thread.
A.
1
/
2
" NPT gas supply line
B.
3
/
8
" NPT dryer pipe
   
A
B
    *6¼"
(159 mm)
   1½"
(38 mm)
*NOTE: If the dryer is mounted on a pedestal, the gas pipe 
 
height must be an additional 10" (254 mm) or 15.5" (394 mm) 
from the floor, depending on the pedestal model. For a garage 
installation, the gas pipe height must be an additional 
18" (460 mm) from the floor.
Make Gas Connection
1. Remove the red cap from the gas pipe. 
2. Using a wrench to tighten, connect the gas supply to the dryer. 
Use pipe-joint compound on the threads of all non-flared male 
fittings. If flexible metal tubing is used, be sure there are no kinks.
A
B
A. Flared male fitting
B. Non-flared male fitting
NOTE: For LP gas connections, you must use pipe-joint 
compound resistant to the action of LP gas. Do not use 
TEFLON
®†
®TEFLON  is a registered trademark of E.I. Du Pont De Nemours and Company.
 tape.
A combination of pipe fittings must be used to connect the dryer 
to the existing gas line. Shown is a recommended connection. 
Your connection may be different, according to the supply line 
type, size and location.
A.
3
/
8
" flexible gas 
connector
B.
3
/
8
" dryer pipe 
C.
3
/
8
" to 
3
/
8
" pipe elbow
D.
3
/
8
" pipe-to-flare 
adapter fitting
A
B
C
D
3. Open the shutoff valve in the supply line. The valve is open when 
the handle is parallel to the gas pipe.
A. Closed valve
B. Open valve
A
4. Test all connections by brushing on an approved noncorrosive 
leak-detection solution. Bubbles will show a leak. Correct any 
 
leak found.
VENTING
Venting Requirements
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death 
or fire.
WARNING: 
To reduce the risk of fire, this dryer MUST BE 
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent, 
chimney, wall, ceiling, attic, crawlspace, or a concealed space 
 
of a building. Only rigid or flexible metal vent shall be used for 
exhausting.
If using an existing vent system
Clean lint from the entire length of the system and make sure 
exhaust hood is not plugged with lint. 
Replace any plastic or metal foil vent with rigid or flexible heavy 
metal vent.
Review vent system chart. Modify existing vent system if 
necessary to achieve the best drying performance. 
If this is a new vent system 
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.