Whirlpool wgd6600 Guia Do Utilizador

Página de 52
6
A grounded electrical outlet located within 2 ft (610 mm) of either 
side of the dryer. See “Electrical Requirements.”
A sturdy floor to support the total weight (dryer and load) of 
 
200 lbs (90.7 kg). The combined weight of a companion 
appliance should also be considered.
Cold water faucets located within 4 ft (1.2 m) of the water fill 
valves, and water pressure of 20-100 psi (138-690 kPa). You 
may use the water supply for your washer using the “Y” 
connector and short hose (if needed) which are provided.
20-100 psi (138-690 kPa) for best performance.
A level floor with a maximum slope of 1" (25 mm) under entire 
dryer.
Do not operate your dryer at temperatures below 45ºF (7ºC). At 
lower temperatures, the dryer might not shut off at the end of an 
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be 
exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes, or 
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the same 
closet as a dryer.
Installation Clearances
The location must be large enough to allow the dryer door to open 
fully. 
Dryer Dimensions
29"
(737 mm)
22
1
/
4
"
(565 mm)
29
1
/
4
"
(743 mm)
43
1
/
2
"
(1105 mm)
*Most installations require a minimum 5" (127 mm) clearance 
behind the dryer for the exhaust vent with elbow. See “Venting 
Requirements.”
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this dryer. 
This dryer has been tested for spacing of 0" (0 mm) clearance on the 
sides and rear. Recommended spacing should be considered for the 
following reasons:
Additional spacing should be considered for ease of installation 
and servicing.
Additional clearances might be required for wall, door, and floor 
moldings.
Additional spacing should be considered on all sides of the dryer 
to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings 
in the top and bottom of the door are required. Louvered doors 
with equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered. 
Additional spacing is required if you exhaust out the rear of the 
dryer to either the right or left side.
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
14" máx.*
(356 mm)
A
B
C
29"
(737 mm)
5"
(127 mm)
1"
(25 mm)
1"
(25 mm)
18"*
(457 mm)
3"*
(76 mm)
3"*
(76 mm)
29
1
/
4
"
(743 mm)
48 in.
2
*
(310 cm
2
)
24 in.
2
*
(155 cm
2
)
*Required spacing
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The installation 
must conform to the Manufactured Home Construction and 
Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal 
Standard for Mobile Home Construction and Safety, Title 24, HUD 
Part 280) or Standard CAN/CSA-Z240 MH.
Mobile home installations require:
Metal exhaust system hardware, which is available for 
purchase from your dealer.
Mobile home Installation Kit Part Number 346764. See “Tools 
and Parts” section for information on ordering.
Special provisions must be made in mobile homes to 
introduce outside air into the dryer. The opening (such as a 
nearby window) should be at least twice as large as the dryer 
exhaust opening.
Electrical Requirements
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING
120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical supply 
is required. A time-delay fuse or circuit breaker is recommended.