Operation 
Initial Startup 
After satisfying the installation requirements, the cream dispenser is ready to start. The unit will start when the power cord is connected 
to a live electrical receptacle. This can be verified by checking the indicator panel on the front of the unit.  The indicator should display 
the current unit temperature.  If the unit does not start when the power cord is plugged in, make sure that the switch on the back of the 
unit is in the ‘on’ position. Allow the unit to run a minimum of two hours before loading it with product.  It is completely normal for the 
exterior of the unit to feel warm while it is running.   
Indicator Panel 
The Indicator Panel contains a digital LED display that reads the product temperature 
during normal operation.  The three lower buttons on the Indicator Panel are for selecting 
portion sizes (small or large).  The upper button is used to reset the computer whenever 
the cream is refilled.  
This button must be pressed each time the 
cream is refilled.  Press and hold the REFILL button for 3 
seconds until the indicator flashes 00.
 
 
Preparation for Use 
Once the unit has achieved proper operating temperature, observe the procedures noted in 
the label on the door liner for loading cream into the cream dispenser. When removing an 
empty bag of cream, be sure to push the Valve Slide in fully before pulling the Dispensing 
Tube out of the valve. It may be easier to remove or install the Dispensing Tube in the 
valve by removing the Valve Insert first then removing or installing the Cream Container.  
The end of the tube may need to be cleaned daily with a clean cloth to prevent buildup 
which could affect the dispensing of product.  After loading the creamer, press and hold 
the REFILL button for 3 seconds until the indicator flashes 00. 
 
 
Defrost: 
The Silver King cream dispenser is a manual defrost unit.  
The unit should be defrosted whenever the walls accumulate 
a frost bank that is 1/2 inch thick.  To defrost the unit, either 
turn the Temperature Control knob to the ‘off’ position or 
disconnect the power cord from the electrical receptacle, 
and open the door.  After the frost has melted or come loose 
from the cabinet walls, wipe out the cabinet interior.  Do not 
attempt to scrape or chisel off the frost as you could do 
irreparable damage to the unit. 
 
MAINTENANCE 
Preventative maintenance is minimal although these few 
steps are very important to continued operation and 
maximizing the life of the appliance. 
 
Cabinet Surfaces: 
The cabinet interior and exterior are stainless steel and 
should be cleaned periodically with a solution of warm water 
and a mild soap, rinsed and wiped dry with a clean soft 
cloth.  A stainless steel cleaner can also be used.  Should a 
surface become stained or discolored, do not attempt to 
clean with an abrasive cleaner or scouring pad.  Use a soft 
cleaner and rub with the grain of the metal to avoid 
scratching the surface.  Do not use chlorinated cleaners. 
 
 
 
 
The REFILL button must be 
pressed for 3 seconds each 
time the cream is replaced  
Indicator Panel
 
The three lower buttons on 
the Indicator Panel are for 
selecting portion size
 
Small
 
Medium
 
Large