Zanussi ZCK68300B Manual Do Utilizador

Página de 28
Use flexible tubing, which comply
with the BS.669 current edition.
B
C
C
D
E
A
WARNING!
The gas bayonet connector must be
in the marked area.
Dimension
mm
A
250
B
680
C
50
D
250
E
580
Pressure test
The Rapid injector is used as a pressure test
point.
1. Connect the pressure gauge to the Rapid
injector.
2. Examine the supply pressure by turning the
Rapid burner and one other burner fully on,
and lighting them. The pressure must be:
a) 20 mbar for Natural Gas
b) 29 mbar for LPG, butane only
c) 37 mbar for LPG, propane only.
3. Turn the taps off and disconnect the
pressure gauge.
4. Make sure that all burners work correctly.
Checking the hob burners
1. Lift the lid.
2. Put on the burner crowns and caps. Make
sure that they are correctly seated.
3. Put on the pan supports.
4. Light one of the hob burners. 
To light the hob burner refer to the "Ignition
of the hob burners".
Check if the flame is regular.
Check each of the burners.
5. Turn the knob for the hob to the off position.
Checking the Lid Safety Device
1. Lift the lid.
2. Light one of the hob burners. 
To light the hob burner refer to the "Ignition
of the hob burners".
3. Close the lid. There should be no gas
supply to the hob burners. The burner goes
out.
4. Turn the knob to the off position and lift the
lid. The gas supply should be restored to
the hob burners, when you turn the knob on.
Electrical installation
WARNING!
The manufacturer is not responsible
if you do not follow the safety
precautions from Safety chapters.
This appliance is supplied without a main plug
or a main cable.
Covering terminal board
• The recommended cross-section area is six
square millimetres (6 mm²).
• When you refit the mains terminal cover,
make sure that the lower tabs are located
inside the bottom edge of the aperture,
before you fix the two screws into the top
edge of the mains terminal cover.
• Make sure that the cover is securely
fastened.
www.zanussi.com