Nokia 5110 Manual Do Serviço
PAMS
Technical Documentation
NSE–1/3
Service Software Instructions
Page 26
Original 03/98
Tuning
The tuning menu offers functions for ME adjustments.
RX Calibration... command
Activation
Status Bar Text
Alt, T,R
Open RX Calibration dialog box
Starts RX calibration.
The next automatic selections are made when this tuning function is acti-
vated:
vated:
•
Phone is set to local mode
•
Update RF information window
The measurement is started automatically when RX calibration is entered.
The measurement is done in five steps:
The measurement is done in five steps:
1. User is requested to put signal generator to high input level (read from
.INI file).
.INI file).
2. Measurement with high input level is executed
3. User is requested to put signal generator to low input level (read from
.INI file).
.INI file).