Alliance Laundry Systems T453I Manual Do Utilizador

Página de 68
Programming the Electronic OPL Control
M414462
24
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Special Cycle Mode
This allows the user to select the number of times the 
tumbler will cycle from heat-on to heat-off. To enter 
the Special Cycle Mode, press the SPECIAL CYCLE 
pad after selecting a cycle. The display will read 
“SC:**”. “**” is the number of times the tumbler will 
cycle from heat-on to heat-off. This number can be 
changed by pressing the MORE or LESS pads. For 
increments of 1, press pad and release. For increments 
of 5, press pad and hold for 3 seconds. Range is from 
1 – 99.
Press the START pad and the number shown after 
“SC:” is the number of cycles selected, the number 
will decrease as each cycle is completed. The default 
cool down cycle for the Special Cycle Mode is 
Automatic Cool Down.
NOTE:  Since there is only 60 minutes of cycle time, 
any cycles not completed within 60 minutes will be 
skipped.
NOTE: Unlike the Time Dry mode and Automatic 
mode, the regulating temperature in the Special 
Cycle Mode has a range of 80°F (27°C) to 180°F 
(82°C) or all heat cycles.
Special Time Mode
This mode is just like the Time Dry mode, except that 
the regulating temperature for each heat cycle ranges 
from 80°F (27°C) to 180°F (82°C). To enter the 
Special Time mode, press the SPECIAL TIME pad 
after selecting a cycle. The display will read “St:**”, 
where “**” is the drying time. This time can be 
changed by pressing the MORE or LESS pads. For 1 
minute changes, press the pad and release. For 5 
minute changes, press the pad and hold. Maximum 
drying time allowed is 60 minutes.
“AC:**” will be displayed when tumbler is in Auto 
Cool Down. Typical cool down times for fabric 
selections are preset. The cool down time can only be 
altered before cycle is started. To alter cool down time 
press the COOL DOWN pad and then press the 
MORE or LESS pad (when cool down time is altered, 
“TC:**” will be displayed). For 1 minute changes, 
press pad and release. For 5 minute changes, press pad 
and hold. Cooling time can be from 1 to 39 minutes. 
To return to the Auto Cool Down, press MORE or 
LESS pad until “AC:**” is displayed.
To start the cycle, press START. The total drying time 
plus cool down time will display. During the cycle, 
remaining time displays.
Security Lock-Out
The programming pads can be “locked-out” so 
operators cannot change cycles on their own. When 
lock-out is used, the operator can use only the factory-
set Automatic cycles and the one Custom cycle 
allowed per Select pad. Before using lock-out, create 
all desired Custom cycles.
To lock-out, hold SIGNAL pad and press MORE in 
the idle mode.
To unlock, hold SIGNAL pad and press LESS in the 
idle mode.
Show Mode
This mode will show all LED’s and light up entire 
display while deactivating all pads. This mode allows 
loading door to be opened and closed. To enter this 
mode, the control must first be in the idle mode. Hold 
the START pad and press the SAVE CUSTOM pad. To 
exit Show Mode, hold the START pad and press the 
SAVE CUSTOM pad.