OTHER KEYPAD FUNCTIONS
SETTING THE KEYPAD TONE
Step 1
Press [
U
]-[0].  Keypad is now in the “Adjust Tone” mode.
Step 2
Pressing  the  [1] key will make the keypad sounder go to higher
tones, pressing the [2] key will make the keypad sounder go to lower
tones.
Step 3
When the desired tone is reached, press the [#] key to set this tone
and exit from the “Adjust Tone” mode.
CHANGE PARTITION – Optional
Step 1
Press [
U
]-[1].
Step 2
Press a NUMBER key (1 or 2) to change partitions momentarily.
Step 3
If no other key is pressed, it will go back to its standard partition in
ten seconds.
Step 4
If another key is pressed, the system will remain in the new partition
until no keys have been pressed for 60 seconds.
VIEW ALARM MEMORY
Step 1
Press  [
U
]-[3].   The zone(s) that created the last alarm will be
displayed on the keypad.
Step 2
The ALARM MEMORY feature will flash those zones that created
alarms and will light steady those zones that were bypassed during
the last alarm.
TEST FUNCTION – Optional
If programmed, this function will perform a battery test, communicator test,
and/or a siren test. No alarms will be sent and no reports will be sent unless a
communicator test is performed, at which time a test signal will be sent.
Step 1
Press [
U
]-[4].  The test will be performed as programmed.
Step 2
If the siren test is performed, enter a user code to silence the siren.