Fujitsu ETERNUS DX60 Manual Do Utilizador

Página de 4
(Front rack pillars)
(Rear rack pillars)
"R" is stamped on the inner 
side of the right rack rail.
"L" is stamped on the inner 
side of the left rack rail.
Loosen the screws, 
and adjust the rack rails to 
the depth of the rack.
[Left]
[Right]
Adjust the rack rail (bracket) 
size to fit the rack.
1.
S T E P
Installation
ETERNUS DX60/DX80
1st position
(M5 screws)
3rd position
(M5 screws)
1st position
(M5 screws)
3rd position
(M5 screws)
2U
[Screw location of the rack rail (bracket)]
Tighten the screws in the same locations on both the front and rear sides of the rack pillars
[Left]
[Right]
Rack rail (bracket)
Base line of the 
ETERNUS DX60/DX80
Make sure to install or remove the enclosure 
to or from the rack by two or more people.
Multiple Drive Enclosures must be connected 
to the controller enclosure following the order 
of the "DE_No. label" numbers attached to 
each Drive Enclosure. The position of the 
labels are in the positions shown below.
IMPORTANT
Between the EXP#0 and 
EXP#1 expanders at the rear 
of the drive enclosure
DE_No. label
At the right side of the front of 
the drive enclosure
S T E P
Cable Connection
When Drive Enclosures are installed, miniSAS cables are 
used to connect between the SAS ports of the enclosures. 
Connect the Controller Enclosure to Drive Enclosure 1, Drive 
Enclosure 1 to Drive Enclosure 2, Drive Enclosure 2 to Drive 
Enclosure 3, etc. The number of Drive Enclosure can be 
checked with the "DE_No." label. 
Various  cables  need  to  be  connected  to  the  rear  of  the 
ETERNUS DX60/DX80.
Rear view
Controller 
Enclosure
Cable
     LAN Cables
     MiniSAS Cables (for Drive Enclosures)
Use release ties to hold the power cords in place.
     Power Cords
Rear view
Controller 
Enclosure
Drive 
Enclosure
Cord
Rear view
Controller 
Enclosure
Drive 
Enclosure
Drive 
Enclosure
Cable
     MiniSAS Cables (for Host Interface)
Rear view
Controller 
Enclosure
Cable
The SAS (OUT) port is on the left side, and 
SAS (IN) port is on the right side.
Insert the connector with a   mark on its 
underside in the SAS (OUT) port.
Insert the connector with a   mark on its underside in the 
SAS (IN) port.  
To help with cable management and prevent 
incorrect connection, attach labels to the cables 
and  make  a  note  of  connection  origins  and 
destinations.
Point
The cables should never be bent, twisted or 
pulled.
IMPORTANT
Underside of 
the SAS (OUT) side plug
Underside of 
the SAS (IN) side plug
The RMT port is on the left  side, and MNT port 
is on the right side. 
The MNT port must always be connected. The 
RMT port only needs to be connected when the remote 
support connection is to be independent of the customer 
network.
For each CM, the port numbers are (left to right) 
0 and 1. Connect a miniSAS cable to each  of 
these ports.
Example for connection of miniSAS cable 
(when two Drive Enclosures are installed)
The rack rail (bracket) needs to be attached to the rack and the ETERNUS DX60/DX80 mounted.
Attach the rack rails (brackets) to the rack. The size of the 
ETERNUS DX60/DX80 is 2U.
2.
Mount the ETERNUS DX60/DX80 in the rack.
3.
Fasten the ETERNUS DX60/DX80 to the rack.
4.
"5.2 Rack Installation" in the "User Guide"
"6.2 LAN Cable Connection (for Operation Management)" in the "User 
Guide"
"6.5 MiniSAS Cable Connection (For  SAS)" in the "User Guide"
"6.6 MiniSAS Cable Connection (For Drive Enclosures)" in the "User 
Guide"
"6.7 Power Cord Connection" in the "User Guide"