4.3  DIGITAL DISPLAY INDICATORS 
4.3.1 DIGITAL DISPLAY ON RFU 
The  digital  display tube  on  RFU  shows  the  DL input  power.  The  range  of  DL input  power  shown  on  the 
display tube is from -19 to 33 (dBm), when DL input power is lower than -19dBm, it will show L, when DL 
input power is higher than 33, it will display H.  
 
 
Figure 35: RFU Digital Display 
 
Table 9: RFU Digital Display  
Figure 
DL Input Power Level 
< -19dBm 
-19~33 
-19~33dBm 
33dBm 
 
 
4.3.2 DIGITAL DISPLAY ON FOU 
The digital display tube on optical module has two digits.  
 
The first digit will display A, b, C and d which presents the No. of optical port. Refer to below figure for the 
relationship. 
 
The  second  digit  will  display  the  optical  loss  of  each port.  See the following  table for the  relationship  of 
figure and optical loss. 
 
A
b
C
d
 
 
Figure 36: Optical Port No. and Digital Display