USER MANUAL FOR COMFLEX-6900  
 
ENU STATUS : 1-0-0 
Copyright - refer to title page 
Page 44 
 
 
 
 
 
RU  device  scanning  is  done.  Note:  Go  to  [Commissioning]  page  or  [Management]  page  for  device 
scanning. 
 
 
Figure45: RU Device 
 
NOTE: There are three statuses for PA Service: NormalRecovery and Shutdown. If PA output power 
or  reflected  power  exceeds  the  threshold  (32dBm  for  LRU,  39dBm  for  MRU),  software  will  trigger 
Recovery:  
 
 
It will reset PA and then re-detect the PA output power and reflected power, if they are normal, the PA 
Service Status will turn to Normal, if PA output power or reflected power is still over the threshold, PA 
Service Status will turn to Recovery again. 
 
If  PA  output  power  or  reflected  power  is  still  over  the  threshold  after  six  times  of  PA  Recovery,  PA 
Service  status  will  be  Shutdown  which  will  need  to  be  reset  manually.Reset  at  Management  >  PA 
Reset. 
 
Click on a specific band on the left side of RU Device page, the corresponding band information will show. 
 
Select band to 
check relative and 
information. 
Band 
information 
table 
RU common 
information table