Risco Ltd. CAV005 Manual Do Utilizador

Página de 64
WatchIN Installation Manual
 
17
1.  To Add / Delete the WatchIN DT 
1.  From the installer menu enter the Add/Delete menu: Quick Key [7][1][9][5] for BUS 
Zones detectors. 
2. Use the 
 / 
 or 
 / 
 keys to position the cursor over the BUS 
Zone ID number for which you want to assign (or delete) a detector.  
Note: 
Make sure that the detector's physical ID number is identical to the ID number you select during programming. 
3.  Place the cursor on the TYPE field and use the 
 / 
 key to select IDT25 for 
the WatchIN DT detector. 
4. Press 
 / 
 to confirm. 
5.  Repeat the process for the other BUS detectors. 
2.  Assigning the WatchIN DT to a Zone 
1.  From the main installer menu enter Zones: One by One option (Quick key [2][1])  
2.  Select the zone number that you want to assign the BUS detector
Note: 
If you have defined a BUS Zone Expander, select a zone number from the virtual zones (defined by the BUS 
zone expander). 
3.  Define Partitions, Groups, Zone Type and Zone Sound. 
4.  In the Termination category select [5] BUS Zone followed by 
 / 
.  
The following display appears:  
 
Z:001    LINK TO:
ID:01  TYPE=IDT25
 
5.  Select the BUS zone number to assign to the programmed zone. The type field will be 
updated automatically when selecting the zone. 
6. Press 
 / 
. The loop response category is not applicable to a BUS zone 
and the following display appears:  
Z:001    RESPONSE:
N/A-BUS ZONE
Z:001    RESPONSE:
N/A-BUS ZONE
 
7. Press 
 / 
, assign label and press
 / 
Configuring the WatchIN DT Parameters 
1.  To access the WatchIN settings option press [2][0][3] from the main installer menu. 
The following display appears: 
 
B- ZONE PRMS:
ZONE#=001   (0:01)
-
 
2.  Select the zone that the BUS zone was assigned to and press 
 / 
. You 
can now program the WatchIN parameters as follows: 
Zones Miscellaneous: BUS Zone 
Quick Keys 
Parameter 
Default 
LEDS 
3 LEDS 
[2][0][3][zzz] 
[1]
 
Defines the LEDS operation mode 
Off 
[2][0][3][zzz] 
[1][1]
 