Risco Ltd. CSMDTN Manual Do Utilizador
GENERAL DESCRIPTION
The COSMOS family includes the following models:
•
COSMOS PR:
A microprocessor based Passive Infrared detector
•
COSMOS AM:
Passive Infrared detector with anti-masking features.
•
COSMOS PET PR:
A microprocessor based Passive Infrared detector with
pet immunity
•
COSMOS PQ:
A Quad PIR with two separate dual element pyroelectric
sensors.
•
COSMOS DT:
A Dual Technology detector offering both MW and IR
technologies.
•
COSMOS DTAM:
A Dual Technology detector with anti-masking features.
•
COSMOS PET DT:
A Dual Technology detector with pet immunity.
The IR responds to changes in the ambient thermal radiation caused when
an intruder crosses the protected area.
an intruder crosses the protected area.
The MW transmits signals and analyzes the frequency changes of the
reflected echo from an intruder due to Doppler effect.
reflected echo from an intruder due to Doppler effect.
An ALARM is initiated only when both technologies trigger simultaneously.
Detection occurs only in areas where IR and MW patterns overlap, greatly
reducing the chance of false alarms.
reducing the chance of false alarms.
The cosmos DT is available in the following versions:
Table 1: Available COSMOS DT Lenses and Accessories.
LED's jumper
LEDS
LEDS
MW
Module
Module
PULSE
Jumper
Jumper
IR Sensor
MW Range
Adjustment
Adjustment
Tamper
Switch
Switch
ACCESSORY
Typical Mounting Height
Typical Mounting Height
2.5m
2.5m
2m
Wide Angle Lens
RL-115
RL-125
Long Range Lens
***
***
RL-17
Corridor Lens
RL-15
***
Pet Alley set
RA-12
***
Ceiling Mounted Swivel
RA-90
***
Wall/Corner Mounted Swivel
RA-91
***
DTI (UK) (10.687 GHz)
RK - 210DTI
RK - 215DTI
RK - 225DTI
RK - 215DTI
RK - 225DTI
RANGE
10m/ 33ft
15m/ 50ft
25m/ 80ft
15m/ 50ft
25m/ 80ft
FCC (USA)
(10.525 GHz)UL Listed
RK - 210FC
RK - 215FC
RK - 225FC
(10.525 GHz)UL Listed
RK - 210FC
RK - 215FC
RK - 225FC
1
RK-225
RK-215
RK-210
CAUTION:
THE UNIT SHOULD NOT BE MOUNTED IN DIRECT SUNLIGHT OR NEAR
ANY HEAT SOURCES. THE DETECTION SECTORS SHOULD BE POINTED
TOWARDS EITHER A WALL OR THE FLOOR (NOT WINDOWS AND
CURTAINS). INSTALL ON SMOOTH SURFACES ONLY.
ANY HEAT SOURCES. THE DETECTION SECTORS SHOULD BE POINTED
TOWARDS EITHER A WALL OR THE FLOOR (NOT WINDOWS AND
CURTAINS). INSTALL ON SMOOTH SURFACES ONLY.
PRELIMINARY CONSIDERATIONS
STEP 2
If a fixing screw is used to secure the front cover, turn the screw 3 full turns
in the counterclockwise direction. With the screw now loosened, press it in
to release the front cover.
If a screw is not used, press the tab located behind the screw hole. The front
cover can now be removed.
in the counterclockwise direction. With the screw now loosened, press it in
to release the front cover.
If a screw is not used, press the tab located behind the screw hole. The front
cover can now be removed.
PC BOARD REMOVAL
STEP 3
Loosen the holding screw located on the right side of the PCB and slide the PCB
up until the screw enters the widened region. The PCB can now be lifted off.
up until the screw enters the widened region. The PCB can now be lifted off.
MOUNTING
STEP 4
The COSMOS DT can be mounted either on flat surface or at corner.
a.
a.
Open the knockout holes on the rear cover.
b.
Insert the cable through the cable hole.
c.
Mount the rear cover in its final location.
d.
Seal the remaining holes with sealant.
e.
After mounting the back cover replace the PCB in its position.
PC BOARD ADJUSTMENT
STEP 5
After the Detector base has been mounted, reinstall the PCB. Use the scale
on the bottom left side of the PCB to choose the correct vertical adjustment
position as follows:
For WIDE ANGLE LENS RK210/RK 215
installed at a height of 2.5m (8’2”) (for UL).
on the bottom left side of the PCB to choose the correct vertical adjustment
position as follows:
For WIDE ANGLE LENS RK210/RK 215
installed at a height of 2.5m (8’2”) (for UL).
Fine Tuning of Protected Area:
Slide the board up -
Slide the board up -
to lower the beams and reduce the range.
Slide the board down - to raise the beams and increase the range.
For LONG RANGE: Select select position, LONG, Pulse Count of 1 and a
mounting height of 2.5m.
When completed, fasten the screw to secure the PCB in the desired position.
For LONG RANGE: Select select position, LONG, Pulse Count of 1 and a
mounting height of 2.5m.
When completed, fasten the screw to secure the PCB in the desired position.
RK-225 install
at 2m (6’7”) at Long position only
SCALE POSITION
short
long
ROOM SIZE
3-6m (9-18ft)
6-15m (18-50ft)
3
PRELIMINARY CONSIDERATIONS
STEP 1
•
Dual IR and MW Technologies
•
Creep Zone
•
Microprocessor Design
•
Automatic True Temperature Compensation
•
Microwave Range Adjustment
•
Pigmented Lenses
•
Alternate Polarity Pulse Count
•
Low Current Consumption
•
High RFI Immunity
•
Anti-Fluorescent Interference Signal Processing
•
Wall and Corner Mounting Without Accessories
•
Vertical Adjustment
•
UL Listed Versions
COSMOS DT FEATURES
When LEDS Jumper is IN:
•
YELLOW LED indicates
PIR detection
PIR detection
•
GREEN LED indicates
MW detection
MW detection
•
RED LED indicates alarm
(simultaneous PIR and
MW detection)
(simultaneous PIR and
MW detection)
•
At Powe-up period, the
Leds will blink
continuously, one after
the other, untill end of
warm-up period.
Leds will blink
continuously, one after
the other, untill end of
warm-up period.
LED display
TAMPER
+ -
LEDS ON
ALARM
C29
+
MU1
+5V
IF
GND
GND
S1
1 T4
C19
C6
C25
C8
LONG
SHORT
MICROWAVE
SENSITIVITY
MIN
MAX
C24
C21
C1
PULSE
OFF
TC1
XTL1
C28
C15
Before installation, carefully study the space to be protected so as to choose
the correct placement of the unit and lens for best coverage.
The detector should be installed so that the beam patterns are at 45º
(optimal) to the intruder's expected path. Corner installations are
recommended. Installation height should be between 1.8m (5’9”) and 2m
(6’7”) for the 225 and at an optional 2.5m (8’2”) for the RL-17. Use Fig 3
as reference.
the correct placement of the unit and lens for best coverage.
The detector should be installed so that the beam patterns are at 45º
(optimal) to the intruder's expected path. Corner installations are
recommended. Installation height should be between 1.8m (5’9”) and 2m
(6’7”) for the 225 and at an optional 2.5m (8’2”) for the RL-17. Use Fig 3
as reference.
INSTALLATION
The IR range is determined by the installation height. Use fig 3 as a
reference. For every 10cm (4") of lowering (or increasing) the
installation height, the range is reduced (or increased) by 2.8m (9'2").
reference. For every 10cm (4") of lowering (or increasing) the
installation height, the range is reduced (or increased) by 2.8m (9'2").
NOTE
2
Fig 1.