Takamisawa NA5WK5V PCB Mount Relay, Subminiature 5V 2 CO, DPDT NA5WK5V Ficha De Dados
Códigos do produto
NA5WK5V
2
NA SERIES
n
SPECIFICATIONS
Standard Type
Single Winding Latching Type Double Winding Latching Type
Item
NA-( ) W-K
NAL-( ) W-K
NAL-D ( ) W-K
Contact
Arrangement
2 form C (DPDT)
Material
Gold overlay silver alloy
Style
Bifurcated
Resistance (initial)
Maximum 50 mΩ (at 1 A 6 VDC)
Rating (resistive)
0.5 A 125 VAC or 1 A 30 VDC
Maximum Carrying Current
2 A
Maximum Switching Power
62.5 AV, 30 W
Maximum Switching Voltage
250 VAC, 220 VDC
Maximum Switching Current
2 A
Minimum Switching Load*
1
0.01 mA 10 mVDC
Capacitance
Approximately 0.5 pF (between open contacts, adjacent contacts)
Approximately 1.0 pF (between coil and contacts)
Coil
Nominal Power (at 20°C)
0.14 to 0.3 W 0.1 to 0.15 W
0.20 to 0.3 W
Operate Power (at 20°C)
0.08 to 0.17 W 0.06 to 0.085 W
0.115 to 0.17 W
Operating Temperature
–40°C to +85°C (no frost)(refer to the CHARACTERISTIC DATA)
Time Value Operate (at nominal voltage)
Maximum 6 ms Maximum 6 ms (set)
Release (at nominal voltage)
Maximum 4 ms
Maximum 6 ms (reset)
Insulation
Resistance (at 500 VDC)
Minimum 1,000 MΩ
between open contacts
1,000 VAC 1 minute
Dielectric
between adjacent contacts
1,000 VAC 1 minute
Strength
between coil and contacts
1,500 VAC 1 minute 1,000 VAC 1 minute
between open contacts
1,500 V (at 10 × 700 µs)
Surge
between adjacent contacts
1,500 V (at 10 × 700 µs)
Strength
between coil and contacts
2,500 V (at 2 × 10 µs) 1,500 V (at 10 × 160 µs)
Life
Mechanical
1 × 10
8
operations minimum 1 × 10
7
operations minimum
Electrical
2 × 10
5
ops. min. (0.5 A 125 VAC), 5 × 10
5
ops. min. (1 A 30 VDC)
Other
Vibration Misoperation
10 to 55 Hz (double amplitude of 3.3 mm)
Resistance Endurance
10 to 55 Hz (double amplitude of 5.0 mm)
Shock Misoperation
500 m/s
2
(11 ±1 ms)
Resistance Endurance
1,000 m/s
2
( 6 ±1 ms)
Weight
Approximately 1.5 g
*
1
Minimum switching loads mentioned above are reference values. Please perform the confirmation test with the actual load
before production since reference values may vary according to switching frequencies, environmental conditions and