Takamisawa NA5WK5V PCB Mount Relay, Subminiature 5V 2 CO, DPDT NA5WK5V Ficha De Dados

Códigos do produto
NA5WK5V
Página de 7
2
NA SERIES
SPECIFICATIONS
 
 
Standard Type 
Single Winding Latching Type  Double Winding Latching Type
 
Item
 
 
NA-(  ) W-K 
NAL-(  ) W-K 
NAL-D (  ) W-K
  Contact 
Arrangement 
2 form C (DPDT)
 
Material
Gold overlay silver alloy
 
Style
Bifurcated
   
Resistance (initial) 
Maximum 50 mΩ (at 1 A 6 VDC)
 
Rating (resistive)
0.5 A 125 VAC or 1 A 30 VDC
 
Maximum Carrying Current
2 A
   
Maximum Switching Power 
62.5 AV, 30 W
 
Maximum Switching Voltage
250 VAC, 220 VDC
 
Maximum Switching Current
2 A
 
Minimum Switching Load*
1
0.01 mA 10 mVDC
   
Capacitance 
Approximately 0.5 pF (between open contacts, adjacent contacts)
   
 
Approximately 1.0 pF (between coil and contacts)
  Coil 
Nominal Power (at 20°C) 
0.14 to 0.3 W                 0.1 to 0.15 W    
  0.20 to 0.3 W
   
Operate Power (at 20°C) 
0.08 to 0.17 W               0.06 to 0.085 W    
0.115 to 0.17 W
   
Operating Temperature 
–40°C to +85°C (no frost)(refer to the CHARACTERISTIC DATA)
  Time Value  Operate (at nominal voltage) 
Maximum 6 ms              Maximum 6 ms (set) 
   
Release (at nominal voltage) 
Maximum 4 ms 
   Maximum 6 ms (reset)
  Insulation 
Resistance (at 500 VDC) 
Minimum 1,000 MΩ
 
between open contacts
1,000 VAC 1 minute
 
Dielectric
 
between adjacent contacts
1,000 VAC 1 minute
 
Strength
 
between coil and contacts
1,500 VAC 1 minute 1,000 VAC 1 minute
 
between open contacts
1,500 V (at 10 × 700 µs)
 Surge
 
 between adjacent contacts
1,500 V (at 10 × 700 µs)
 
Strength
 
between coil and contacts 
2,500 V (at 2 × 10 µs)                                            1,500 V (at 10 × 160 µs)
 Life
Mechanical
1 × 10
8
operations minimum 1 × 10
7
operations minimum
 
Electrical
2 × 10
5
ops. min. (0.5 A 125 VAC), 5 × 10
5
ops. min. (1 A 30 VDC)
 Other
Vibration Misoperation
10 to 55 Hz (double amplitude of 3.3 mm)
 
Resistance Endurance
10 to 55 Hz (double amplitude of 5.0 mm)
 
Shock Misoperation
500 m/s
2
(11 ±1 ms)
 
Resistance Endurance
1,000 m/s
2
 (  6 ±1 ms)
 
Weight
Approximately 1.5 g
*
1
  Minimum switching loads mentioned above are reference values. Please perform the confirmation test with the actual load 
before production since reference values may vary according to switching frequencies, environmental conditions and