<Functions of System Menu>
● Select the function name 
and return to the System 
menu  by  touching  the 
R T N   b u t t o n .   O r   t h e  
H O M E / E X I T   b u t t o n   i s 
pushed.
<SensorTouch™>
RETURN
LCD contrast adjustment
1. Select "CONTRAST" and touch the RTN button 
to switch to the data input mode and adjust 
the contrast by scrolling the touch sensor.
  "CONTRAST":  Adjust  the  contrast  to  the 
desired  value  while  watching  the  screen 
display.
  Setting range: (Lighter) 0 to 15 (Darker)
  Initial value: 5
*When you want to reset the value to the initial state, touch 
the RTN button for one second.
2. Touch the RTN button to end adjustment and 
return to the cursor mode.
Back-light brightness adjustment
1. Select  "BRIGHTNESS"  and  touch  the  RTN 
button to switch to the data input mode and 
adjust the back-light brightness by scrolling 
the touch sensor.
  "BRIGHTNESS": Adjust the brightness to the 
desired  value  while  watching  the  screen 
display.
  Setting range: OFF, 1 to 20(Lighter)
  Initial value: 10
*When you want to reset the value to the initial state, touch 
the RTN button for one second.
DISPLAY
LCD and back-light adjustment, unit system
LCD contrast, back-light brightness and back-
light off-timer adjustment are possible:
Moreover, a display unit can be chosen from the 
metric system or yard/pound. 
2. Touch the RTN button to end adjustment and 
return to the cursor mode.
Back-light off-timer
1. Select "OFF TIMER" and touch the RTN button 
to switch to the data input mode and adjust 
the back-light off-timer by scrolling the touch 
sensor.
  "OFF TIMER": Adjust the time when the back-
light  turns  off  after  operating  the  touch 
sensor.
  Setting range: 10 to 240 sec (each 10 sec), 
OFF (always on)
  Initial value: 10 sec
*When you want to reset the value to the initial state, touch 
the RTN button for one second.
2. Touch the RTN button to end adjustment and 
return to the cursor mode.
Unit system adjustment
1. Select "UNIT SYS." and touch the RTN button 
to switch to the data input mode and adjust 
the unit by scrolling the touch sensor.
  Setting range: (METRIC) or (YARD/POUND)
 
2. Touch the RTN button to end adjustment and 
return to the cursor mode.
● Select [DISPLAY] at the system menu and access 
the setup screen shown below by touching the 
RTN button.
Scrolling
● Moving cursor
● Adjusting value