The four pulse generators have default I/O assignments; however, they can be configured to 
any digital output on the CPU or SB. Pulse generators on the CPU cannot be assigned to 
SMs or to distributed I/O. 
 
 
Note 
Pulse-train outputs cannot be used by other instructions in the user program 
When you configure the outputs of the CPU or signal board as pulse generators (for use with 
the PWM or motion control instructions), the corresponding output addresses no longer 
control the outputs. If your user program writes a value to an output used as a pulse 
generator, the CPU does not write that value to the physical output.  
 
 
Table 10- 1  Maximum number of controllable drives 
Type of CPU 
Onboard I/O; 
No SB installed 
With an SB  
(2 x DC outputs) 
With an SB  
(4 x DC outputs) 
With 
direction 
Without 
direction 
With 
direction 
Without 
direction 
With 
direction 
Without 
direction 
CPU 1211C 
DC/DC/DC 
AC/DC/RLY 
DC/DC/RLY 
CPU 1212C 
DC/DC/DC 
AC/DC/RLY 
DC/DC/RLY 
CPU 1214C 
DC/DC/DC 
AC/DC/RLY 
DC/DC/RLY 
CPU 1215C 
DC/DC/DC 
AC/DC/RLY 
DC/DC/RLY 
CPU 1217C 
DC/DC/DC 
 
 
 
Note 
The maximum number of pulse generators is four. 
Whether you use onboard I/O, SB I/O, or a combination of both, you can have a maximum 
number of four pulse generators.