Easy to create the device configuration 
 
5.5 Configuring the operation of the CPU and modules 
Easy Book 
Manual, 03/2014, A5E02486774-AF 
79
 
 
Table 5- 3 
Clock memory  
Bit number 
Tag name 
 
 
 
 
 
 
 
 
Period (s)  
2.0 
1.6 
1.0 
0.8 
0.5 
0.4 
0.2 
0.1 
Frequency (Hz) 
0.5 
0.625 
1.25 
2.5 
10 
 Because clock memory runs asynchronously to the CPU cycle, the status of the clock memory can change several times 
during a long cycle. 
Configuring the operation of the I/O and communication modules 
To configure the operational parameters for the signal module (SM), signal board (SB), or 
communication module (CM), select the module in the Device view and use the "Properties" 
tab of the inspector window.  
 
 
Signal module (SM) and signal board (SB) 
 
Digital I/O: Configure the individual inputs, such as 
for Edge detection and "pulse catch" (to stay on or 
off for one scan after a momentary high- or low 
pulse). Configure the outputs to use a freeze or 
substitute value on a transition from RUN mode to 
STOP mode. 
●  Analog I/O: Configure the parameters for individual inputs (such as voltage / current, 
range and smoothing) and also enable underflow or overflow diagnostics. Configure the 
parameters for individual analog outputs and enable diagnostics, such as short-circuit (for 
voltage outputs) or overflow values. 
●  I/O addresses: Configure the start address for the set of inputs and outputs of the 
module.