Bradley Brand Furniture COMBI5500 Manual Do Utilizador

Página de 6
17" Chase-Mounted Five-Sided Stainless Steel combination Unit
Installation Instructions
COMBI5500
3
Bradley Corporation • 215-329 Rev. J; EN 04-732C
6/28/04
Installation Instructions
Supplies Required:
• 1" NPT supply piping to flush valve
• Toilet/Lav waste connections
• For optional air valve manifold or self-closing valve: 1/2" NPT supply piping
• For optional Touch Time™ solenoid valve:
1/8" NPT supply piping
Wire nuts sized for 22 AWG wire to connect to 24 VAC power source
Step 1: Roughing-In Supplies, Drain, and Waste Outlet
1. Rough-in wall opening using one of the three versions shown in Figure 1 on page 4.
2. Rough-in water supply(s) for lavatory:
• 1/2" NPT connection required when piping in for air valve manifold (length of tubing
supplied). For air valve manifold assembly installation, refer to Bradley Installation Manual
(part no. 215-1158) provided with the manifold assembly.
• 1/2" NPT connection required when piping in for self-closing valve. For self-closing valve
assembly installation, refer to Bradley Installation Manual (part no. 215-581) provided with
the self-closing valve assembly.
• 1/8" NPT connection required when piping in for Touch Time™ solenoid valve. (Note:
Length of tubing supplied.) For Touch Time™ solenoid valve installation, refer to Bradley
Installation Manual (part no. 215-1378) for Touch Time™ solenoid valve assembly .
3. Rough-in a 1-1/4" or 1-1/2" NPT (size dependent on options ordered) lavatory waste  outlet at
the dimensions shown in Figure 1.
4.  Rough-in a 1" NPT supply inlet to flush valve.
5. Rough-in a toilet waste outlet at the dimension shown in Figure 1 (waste outlet size dependent
on options ordered).