Symmetricom Time Server Manual Do Utilizador
6000-100Ch2.fm Rev. D
TimeVault™ User’s Manual
2-11
2
Installation and Start-Up
2.1
Site Preparation
2.1.1
Mounting Instructions
To securely mount TimeVault in any EIA standard 19-inch (48.26-cm) rack system, use
the equipment supplied in Symmetricom’s Rack Mount Kit and follow the steps outlined
below.
the equipment supplied in Symmetricom’s Rack Mount Kit and follow the steps outlined
below.
The Rack Mount Kit contains:
• 2 mounting brackets (part number 206-719)
• 4 flat-head, Phillips screws (part number 241-008-005, 8-32 x 5/8)
To rack mount TimeVault:
1. Remove and discard the two factory-installed flat head (Phillips) screws from the front
end of a TimeVault side panel.
2. Place a rack mount bracket on the side panel, so that the countersunk screw holes in
the bracket line up with the screw holes in the panel.
3. Place 2 flat-head Phillips screws from the Rack Mount Kit through the holes in the
bracket and into TimeVault.
4. Tighten the screws to the following specifications:
Use a #2 size Phillips bit with an inch ounce torque setting of 4 ¼ to 4 ¾ (high).
5. Repeat steps 1-4 to install the other rack mount bracket on the unit’s other side panel.
Replace the factory-installed
screws with screws from
the Rack Mount Kit
screws with screws from
the Rack Mount Kit