Symmetricom Time Server Manual Do Utilizador

Página de 148
6000-100Ch2.fm  Rev. D
TimeVault™ User’s Manual
2-29
DHCP Configuration
Chapter 2: Installation and Start-Up
9. End the configuration sequence by pressing SAVE.
TimeVault automatically resets if you have saved any changes to any network 
parameter (excluding Remote Control), and sets the operating speed at 10Base-T.  
Go to the section “Verify Functionality” to verify the operation of the TimeVault.
2.6
DHCP Configuration
The easiest way to configure the network parameters is via Dynamic Host Configuration 
Protocol (DHCP).  If your network has a DHCP server installed (check with your system 
administrator), you can use this service to set up your TimeVault.  The TimeVault is 
shipped with DHCP turned off.  To enable DHCP, use the following procedure:
1. Press the SETUP button several times until the message 
DHCP status OFF
 is displayed.
2. Use the  
↑ and ↓ buttons to turn DHCP on.  
3. Press the SAVE button to store the new setting.
4. Press SAVE again to scroll through the remaining messages.
5. The TimeVault will then reset itself.  During the boot process, it will request network 
settings from the DHCP server, and then will be available on the network.
6. Press the SETUP button to find the assigned IP address.  Then go to the section 
“Verify Functionality” to verify the operation of the TimeVault.
2.7
Verify Functionality
To verify that the unit is running:
1. Ping the NET Port IP Address.
2. If this action fails, check the configuration values assigned to the NET Port.  Correct 
parameters as necessary using the front panel keypad, described above, or the 
serial/Telnet Function F100 IC command, described on page 4-64.
3. If ping fails again, verify with your system administrator that the values used are 
correct.  Then re-enter parameters as necessary.
2.8
Wrap-Up & Advanced Operation
When the LAN interfaces are operational and time is being reported, the unit has achieved 
its basic level of functionality.  For “quick start” information, see the Quick Start card that 
came packaged with this manual.  For remote operation, see Chapter 3.  For details on 
serial/Telnet commands, see Chapter 4.
If you wish to configure NTP client mode, or to use SNMP (TimeVault supports a SNMP 
version 1 agent with the MIB II and Enterprise MIB databases), you must first edit the 
ntp.conf and snmp.conf files (see Section 4.4.12 “F100 CONFIG – FTP Configuration of 
NTP, SNMP & ACTS Parameters” on page 4-67 for details).