Symmetricom Time Server Manual Do Utilizador

Página de 148
6000-100Ch4.fm  Rev. D
TimeVault™ User’s Manual
4-51
Command List
Chapter 4: Serial or Telnet I/O Functions
4.2
Command List 
The following table lists all serial/Telnet commands that are used to operate, administer, 
and maintain the unit.  The Utility Port is ready to receive these commands once the 
power-up sequence is complete.  The F100 series is used mainly to request or set unit NET 
Port  parameters.  Configuration of the IP Address, Subnet Mask, Default Gateway, and 
DHCP parameters is also available through the front panel keypad.  Changing any 
network parameter causes the unit to reboot.
Table 4-1:  F-Series Function Commands 
Use the front panel keypad to set initial system configuration values at first installation.
Command
Function
Parameters
F03
Time/Date Request
MM/DD/YYYYHH:MM:SS
F18
Software Version Request

(equivalent to F100 VER)
F36
Network Configuration Entry/Request
EA, IP, SM, G 
(equivalent to corresponding F100 commands)
F53
Operating Mode Request
F60
Satellite List Request
F67
Leap Second Information Request
F72
Fault Status Request
F100 BASET
100Base-T/10Base-T Entry/Request
10, 100
(change requires confirmation within 10 seconds)
F100 DHCP
DHCP Control
ENABLE/DISABLE
(change requires confirmation within 10 seconds)
F100 EA
Ethernet Address
F100 IP
IP Address
### ### ### ###
(change requires confirmation within 10 seconds)
F100 SM
Subnet Mask
### ### ### ###
(change requires confirmation within 10 seconds)
F100 G
Default Gateway
#### #### #### ####
(change requires confirmation within 10 seconds)
F100 IC
Network Configuration Request
IP, SM, G
F100 P
Password Change Request
XXXXXXX
F100 ST
Self Test Results Request
F100 VER
Software Version Request
F100 T 
Request Current Time Source
GPS, ACTS, or NTP
F100 CONFIG
NTP, SNMP and ACTS Configuration
“GET” , “SET”, “NTP”, “SNMP”, “ACTS”,  “IP 
ADDRESS”, “YES”, “NO”, “W”, “R”
(change requires confirmation within 10 seconds)
F100 LOCK
Remote Lockout
LOCK
(change requires confirmation within 10 seconds)
F100 L
Lock Display Request