SMC Networks TIGERSWITCH 10/100 Manual Do Utilizador

Página de 318
C
OMMAND
 L
INE
 I
NTERFACE
3-68
Line Commands
You can access the onboard configuration program by attaching a 
VT100 compatible device to the server’s serial port. These 
commands are used to set communication parameters for the serial 
port or Telnet (i.e., a virtual terminal).
Command
Function
Mode Page
line 
Identifies a specific line for configuration and 
starts the line configuration mode
GC
login 
Enables password checking at login 
LC
password 
Specifies a password on a line
LC
exec-timeout  Sets the interval that the command 
interpreter waits until user input is detected
LC
password-th
resh
Sets the password intrusion threshold, which 
limits the number of failed logon attempts 
LC
silent-time* 
Sets the amount of time the management 
console is inaccessible after the number of 
unsuccessful logon attempts exceeds the 
threshold set by the password-thresh 
command
LC
databits* 
Sets the number of data bits per character 
that are interpreted and generated by 
hardware
LC
parity* 
Defines the generation of a parity bit
LC
speed* 
Sets the terminal baud rate
LC
stopbits* 
Sets the number of the stop bits transmitted 
per byte 
LC
show line 
Displays a terminal line's parameters
NE, 
PE 
* These commands only apply to the serial port.