Sierra Products EF-5001UB Manual Do Utilizador

Página de 11
4
Figure 7  Rear Connection Panel
Figure 8 Stove Connection Panel
Autolite Wiring Diagram
UNIT  INSTALLATION
Route the power supply cord so that it does not touch
any of the exterior com ponents of the he ater.
1.
W hen exiting through the wall with your type L Pellet
vent p ipe, you  m ay go straight ou t throu gh  a wall
thim ble.  You m us t co nn ec t a p ellet vent te e at this
point and  exte nd th e vent pipe  at leas t 3' (three  feet)
vertically outside to provide good draft and allow the
gases to exit. The tee must have a clean out cap for
inspection and regular cleaning (Figure 4). Horizontal
runs must be limited to 2' (two fe et). A w all ban d is
requ ired fo r ev ery 4' (four feet) minimum  on a vertical
run at an  exterior wa ll.
2.
All pellet vent pipe connections including exit at the
rear of the heater should be sealed with high
tem pe rature silicone  (45 0°) or m eta llic duc t tap e. T his
prevents smok e and soot leakage into the living area.
If this is not done, there is a possibility that the room
fan will pick up any leakage and blow it into the room.
AUTOLITE INSTALLATION INSTRUCTIONS
  Th e A uto Lite  Sys tem  is fa cto ry ins talle d w ith th e only
installation  requ irem ents  being  the optiona l therm osta t.
Wall Thermostat Installation:
  Th e wa ll therm osta t is des igned to autom atically reg ulate
the room tem perature from the control panel heat setting
to the “Off” setting based upon room temperature.
Rem ember to leave the control panel on the "Medium or
High" position when utilizing the wall thermostat feature.
  The following is a step by step procedure for installing the
optional wall therm ostat. Note conne ction terminals on left
side of unit at rear (Fig ure  7,8). Use 18/2 therm ostat wire
for the installation.
a. Unplug he ater from  wall outlet and 12V DC  power!
b. Rem ove factory jump wire and hook up thermostat
wires to terminals (Fig ure  7,8).
c. Locate thermostat approximately 10 to 12 feet from
heater or in area that requires steady temperature.
d. Run thermostat wires from heater to thermostat
along wa ll or und er ca rpet e tc. an d ho ok  wires  to
thermostat terminals.  On new construction you
can, of course, run wire in the walls before sheet
rock or paneling is done.
e. Reco nnect AC  power.
f. Make sure all wiring is completed before plugging
the E AS YFIR E H eate r bac k into  the w all outlet.
IMPORTANT - Any electrical work performed on the
EA SY FIRE H ea ter shou ld  be don e by qualifie d perso nn el.
Remote Control Thermostat Installation:
  Th e re m ote  the rm os tat is  desig ne d to  autom atic ally
regulate the room temperature from the control panel heat
setting to the “Off” setting base d upon roo m  temp erature
and  place m ent o f the re m ote therm osta t. Rem em ber to
leave the control panel on the "Medium or High" position
when utilizing the wall thermostat feature.
  The following is a step by step procedure for installing the
optional remote thermostat. Note connection terminals on
rear  of un it (Fig ure  1,2).
a. Unplug he ater from  wall outlet and 12V DC  power!
b. Mount millivolt style remote receiver box to rear of
stove using double-sided tape.
b. Rem ove factory jump wire and hook up thermostat
wires to terminals (Fig ure  7,8).
d. Re con nec t AC  pow er an d follow  instructions  with
remote thermostat regarding set up.
IMPORTANT - Any electrical work performed on the
 EA SY FIRE H ea ter shou ld  be don e by qualifie d perso nn el.
DOOR HANDLE ASSEMBLY
The door handle and latch must be assembled and adjusted
prior to the operation of the stove.
1.
Position hand le ass em bly throu gh d oor a nd s ecu re with
collar by sliding over shaft and tightening with allen
wrench provided (Figure 9).
2.
Position latch on end of shaft with flat facing allen screw.
Depending on gasket, shaft will protrude approx. 1/4"
through back of latch collar. Snug allen screw.