Maxon Telecom MODMAX MM-6280IND Manual Do Utilizador

Página de 70
 
 
Extended AT Commands Manual 
Page 58 of 70 
2009-06-25 
Register  Value 
Description 
Packet 
Data 
STU-
III 
S7 
1 to 255 
[50] 
Number of seconds to establish end-to-end data 
connection. 
O N/A 
S8 
0 to 255 
Number of seconds to pause when “,” is 
encountered in dial string. 
N/A N/A 
[S9] 
0 to 255 
Carrier detect threshold in increments of 0.1 
seconds. 
N/A N/A 
S10 
1 to 254 
[14] 
[255] 
Number of tenths of a second from carrier loss to 
disconnect. 
[255: Disable carrier detect.] 
N/A N/A 
[S11] 
50-255 
95 
DTMF tone duration and spacing in milliseconds.  
: Only AT command originated DTMF tones are supported. 
N/A N/A 
12.2.3.  Basic action command set 
The following table specifies the Basic action command set to be supported for the data services. 
Exceptions to EIA/TIA-602 are indicated by square brackets. Default settings are shown in bold. 
Table 12.80 Basic action commands 
Command 
Description 
A/ 
Re-execute previous command. 
Enter the online state. See service specific processing for further details. 
D<dial string> 
Causes the MT2 to transition from the command state to the online state. The <dial 
string> is optional. For circuit switched data services, the dial string may contain 
the following characters: Digits 0 to 9, *, #, A, B, C, and D. 
The dial string may contain the following dial modifiers: 
T Tone 
dialling 
[ignore] 
Pulse dialling [ignore] 
Pause during dialling 
Wait for dial tone 
Wait for quiet answer 
! Hook 
flash 
[$] 
Wait for billing tone (for credit-card calls) 
After dialling, the IWF enters the online command state and maintains the 
connection 
H0 
Causes the MT2 to transition from online command state to command state. Use of 
the digit ‘0’ is optional (see EIA/TIA-602). 
O0 
Causes the MT2 to transition from online command state to online state. Use of the 
digit ‘0’ is optional (see EIA/TIA-602).