Emerson 3051N Manual Do Utilizador
Reference Manual
00809-0100-4808, Rev CA
June 2008
Rosemount 3051N
5-2
Environmental
Performance to normal operating limits as described in the “Performance
Specifications” and “Functional Specifications” sections of this manual.
Specifications” and “Functional Specifications” sections of this manual.
Quality Assurance
Program
Program
In accordance with 10CFR50 Appendix B, ISO 9001:2000
Nuclear Cleaning
To <1 ppm chloride content
Hydrostatic Testing
Model
Range Code
Hydrostatic Test Pressure
(1)
3051ND
0
1
1
2–5
750 psi
2000 psi
4200 psi
2000 psi
4200 psi
3051NG
2–5
150% of maximum working pressure
(2)
3051NA
(3)
1–4
(1) Process O-ring Code A (glass-filled TFE).
(2) Maximum Working Pressure equals upper range limit (URL).
(3) Hydrostatic testing not performed on Rosemount 3051NA Range Code 0.
(2) Maximum Working Pressure equals upper range limit (URL).
(3) Hydrostatic testing not performed on Rosemount 3051NA Range Code 0.