Audio-Technica SMARTMIXER AT-MX351 Manual Do Utilizador

Página de 15
The preamplifier gain may be reduced further, allowing the SmartMixer to accept line-level
sources. Changing the settings of the internal switches designated by “SW3,” “SW9,” “SW15”
and “SW21” will cause an input reduction of 50 dB for channels 1, 2, 3 and 4 respectively. 
Note that the appropriate internal switches can be used in combination for a total sensitivity 
reduction of up to 60 dB for each channel. 
Output Level
The SmartMixer’s output is factory set at line level. Should mic-level output be desired, 
simply unplug the unit, remove the top cover and locate the switch on the circuit board
marked “SW26” (Figs. 4 and 5, page 11). Changing the setting of this switch will cause a 
50 dB reduction in output.
Phantom Power
Each of the SmartMixer’s inputs supplies +48V DC phantom power. Should it be required 
to disable the phantom power, simply unplug the unit, remove the top cover and locate the
switches designated on the circuit board by “SW1,” “SW7,” “SW13” and “SW19” (Figs. 4 and 5,
page 11). Changing the settings of these switches will disable phantom power on channels 1,
2, 3 and 4, respectively. Note that, although they do not require phantom power for operation,
most balanced-output dynamic microphones can be used without disabling the SmartMixer’s
phantom power.
Output Level LED Meter
The Output Level LED meter is factory set to indicate RMS output. Should peak output 
indication be desired, simply unplug the unit, remove the top cover and change the setting of
the switch designated on the circuit board by “SW27” (Figs. 4 and 5, page 11). “Zero” (0) level
is factory-calibrated at +4 dBm into 600 ohms.
10
Summary of Internal Controls
Function
Ch 1
Ch 2
Ch 3
Ch 4
Output
48V Phantom Power
SW1
SW7
SW13
SW19
10 dB Input Atten.
SW2
SW8
SW14
SW20
50 dB Mic /Line Atten.
SW3
SW9
SW15
SW21
SW26
Limiters (on/off)
SW4
SW10
SW16
SW22
“Off ” Atten. Range
SW5
SW11
SW17
SW23
Preamp Output Gating
SW6
SW12
SW18
SW24
Limiter Thresholds
VR2
VR5
VR8
VR11
“Off ” Atten. Adjustment
VR3
VR6
VR9
VR12
NOMA
--
--
--
--
SW25
Meter RMS/Peak
--
--
--
--
SW27
Figure 3. Summary of internal controls