4.2 CHECK GAS PRESSURE
Remove the pressure test point screw located on the 
injector feed pipe just left of centre on the fire. Connect a 
pressure gauge, slide the control knob down to the 
PILOT/IGNITION position. Keep the knob depressed 
after the pilot has lit to activate the FSD and then slide the 
knob to the HIGH position. Check that the gas pressure is 
as specified in Section 1.0 Technical Data. Turn off the fire 
and disconnect the pressure gauge. Replace the test 
point screw, relight the fire and test for gas soundness 
around the sealing screw using a suitable leak detection 
fluid.
4.3 FIT OUTER CASE
Align the bottom cut-outs in the outer case with the 
retaining lugs on the firebox sides. Raise the outer case 
vertically and then lower to engage the top onto the lugs 
above the air guide, at the same time ensure that the 
bottom cut-outs remain on the retaining lugs.
Fig. 7C
Fig. 7D