2.2.3 METAL FLUE BOX/125mm DIAMETER FLUES 
   (Figs. 3A and 3B)
This fire may be installed in a double walled or insulated 
metal box built to the requirements of B.S. 715 e.g. 
Selkirk, Product Code Number 0404805, using our 
fixing kit G.C. Number 159 634 ÿ Number 992137. 
The box must be lagged as detailed in Fig. 3B and 
mounted on a non-combustible plinth at least 25mm 
thick. Ensure that the base of the opening is level with 
the hearth. A larger box built to the requirements of B.S. 
715 and insulated as in Fig. 3B may be used. The front 
opening must be as shown in Fig. 3A. The flue should 
be twin walled e.g. Selkirk IL flues, or insulated type of 
at least 125mm internal diameter and with a minimum 
effective height of 3 metres. The depth of the opening 
must be at least 200mm.
NOTES:
1.
If the flat area around the front opening of the box 
is less than as specified in Fig. 1, it may be 
necessary to use additional sealing material to 
achieve a good seal.
2.
The flue spigot restrictor MUST NOT be fitted.
Fig. 3B
Refer to the following 
illustrations for 
configuration.
Cover the top, rear and 
sides of the fire housing as 
shown with 100mm (4in) 
loft insulation material as 
shown. If the gap between 
the fire housing and any 
combustible material is 
less than 100mm, squeeze 
the insulation material 
between the two surfaces.
The minimum distance 
from any studding or other 
combustible material and 
the flue pipe or any part of 
the fire housing must be 
25mm (1in).
Note: The plaster board does not overlap the 
edge of the fire housing. Any non-combustible 
fire surround material used overlaps as 
shown. The non-combustible fire surround 
material must be sealed to the fire housing.
Non-combustible fire
surround material
The non-combustible material 
must be sealed to the fire 
housing to form an air tight seal 
all around.
Non-combustible fire
surround material
Fire housing
Sealant
Fig. 3A
FREESTANDING
GAS FLUE BOX
SELKIRK CODE 0404805
125 I/D
98
FL
UE
CE
NT
RE
45
7
6
1
0
21
2
40
7
5
6
0
20
0