Symptom: 
What it may indicate: 
What you should do: 
10.0  Air charging 
system doesn’t 
build air. 
(a) Governor  malfunction*. 
(b) Restricted discharge line.
(c) Air dryer heater malfunction: 
exhaust port frozen open.
(d) Compressor malfunction.

Go to Test 4 on page 25.

See 9.0(f).

Replace air dryer heater.

Replace the compressor only after making 
certain the preceding conditions do not 
exist.
11.0 Compressor 
safety valve 
releases air 
(Compressor
builds too much 
air).
(a) Restricted discharge line. 

If discharge line is restricted:

By more than 1/16" carbon build up, 
replace the discharge line (see Table A, 
column 2, on page 13 for recommended 
size) and go to Test 3 on page 24.   

By other restrictions (e.g. kinks). 
Replace the discharge line. See Table A, 
column 2, on page 13 for recommended 
size.

The discharge line must maintain a 
constant slope
 down from the compressor 
to the air dryer inlet 
fi
 tting to avoid low points 
where ice may form and block the 
fl
 ow. 
If, instead, ice blockages occur at the air 
dryer inlet, insulation may be added here, 
or if the inlet 
fi
 tting is a typical 90 degree 
fi
 tting, it may be changed to a straight or 
45 degree 
fi
 tting.  For more information on 
how to help prevent discharge line freeze-
ups, see Bendix Bulletins TCH-008-021 
and TCH-008-022 (Appendix B).  Shorter 
discharge line lengths or insulation may be 
required in cold climates. 

Inspect air lines and verify check valves are 
operating properly.  

Ensure discharge line is installed into the 
inlet of the air dryer and delivery is routed 
to the service reservoir.

Verify relief pressure is 250 psi. Replace if 
defective.

Go to Test 6 on page 25.

Go to Test 4 on page 25.
Damaged
discharge
line shown.
* Note: For the Bendix
®
 DuraFlo 596
air compressor, not only 
the governor, but also the SV-1
 synchro valve used would 
need to be tested.  See Bulletin TCH-001-048.
(b) Downstream air brake system check 
valves or lines may be blocked or 
damaged.
(c) Air dryer lines incorrectly installed. 
(d) Compressor safety valve 
malfunction.
(e) Compressor unloader mechanism 
malfunction.
(f)  Governor malfunction.