BENDIX SD-01-700 Manual Do Utilizador
25
1. Ensure that the governor control line from the
reservoir is located at or near the top of the
reservoir. (This line, if located near the bottom of
the reservoir, can become blocked or restricted
by the reservoir contents e.g. water or ice.)
reservoir. (This line, if located near the bottom of
the reservoir, can become blocked or restricted
by the reservoir contents e.g. water or ice.)
Bendix
®
Compressors:
Park vehicle, chock
wheels, and follow all standard safety procedures.
Remove the governor and install a
Remove the governor and install a
fi
tting to the
unloader port. Add a section of air hose (min
1 ft long for a 1/2" diameter line) and a gauge
to the
1 ft long for a 1/2" diameter line) and a gauge
to the
fi
tting followed by a shut-off valve and an
air source (shop air or small air tank). Open the
Test 5: Governor Control Line
Test 6: Compressor Unloader Leakage
1. Inspect control lines to and from the governor
for restrictions (e.g. collapsed or kinked).
Repair as necessary.
Repair as necessary.
2. Using a calibrated external gauge in the
supply reservoir, service reservoir, or reservoir
port of the D-2
port of the D-2
®
governor, verify cut-in and
cut-out pressures are within vehicle OEM
speci
speci
fi
cation.
3. If the governor is malfunctioning, replace it.
Tests (continued)
Test 4: Governor Malfunction
2. Perform proper reservoir drain intervals and air
dryer cartridge maintenance per Maintenance
Schedule and Usage Guidelines (Table A on
page 13).
Schedule and Usage Guidelines (Table A on
page 13).
3. Return the vehicle to service.
shut off and charge the unloader port by allowing
air pressure to enter the hose and unload the
compressor. Shut off the air supply and observe
the gauge. A steady reading indicates no leakage
at the unloader port, but a falling reading shows
that the unloader mechanism is leaking and needs
to be serviced.
air pressure to enter the hose and unload the
compressor. Shut off the air supply and observe
the gauge. A steady reading indicates no leakage
at the unloader port, but a falling reading shows
that the unloader mechanism is leaking and needs
to be serviced.