TROUBLESHOOTING
Problem
Possible Cause
Remedy
Power
1.A circuit breaker may have
Reset circuit breaker or
unit does
tripped or a fuse has blown
replace fuse.
not
in the power supply circuit.
function
2.The built-in safety cutout
If the safety has tripped due to
may have tripped.
overheating:
> Turn the power unit to the Off
position, “O/Off,” and unplug.
> Remove the attachment that was
in use when safety tripped, and
correct whatever the situation
is that caused the safety to trip.
> Wait a few minutes (minimum 30
minutes recommended) to allow
the motor to cool.
> Depress the manual reset button
on the bottom of the power unit,
see figure 2b.
> Reinstall the attachment and
resume use per attachment’s
instructions.
Power
1.The motor has become
> Turn the power unit to  the Off
unit hums
blocked; that is, the
position, “O/Off,” and unplug.
but
attachment being used has
> Remove the attachment
nothing is
become jammed.
that was in use and correct
moving
whatever the situation is that
is causing the blockage.
> Reinstall the attachment and
resume use per attachments
instructions.