Fujitsu DX60 Manual Do Utilizador

Página de 122
Appendix A  Event Notification Message List
  A.2  Message List
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
116
Copyright 2012 FUJITSU LIMITED
P3AM-5512-03ENZ0
A.2.5
Test Messages
The messages that are sent when the test notification of an event is performed in ETERNUS 
Web GUI or ETERNUS CLI are described below.
Send Test E-Mail
The message is notified when the test notification of e-mail is performed in ETERNUS Web GUI 
or ETERNUS CLI.
Test Trap transmission
The message is notified when the test notification of the SNMP Trap is performed in ETERNUS 
Web GUI or ETERNUS CLI.
A.2.6
Sense Codes
This section describes the sense codes that are notified to the server.
Event type and event code
Message
T FFFFFFFF
Test E-mail Message
Trap No.
TrapItemId
TrapMessage
2
0x80000000
SNMP Trap Test
The Trap No. and ItemId in the test Trap are the same as the notification 
that is sent when the disk in Slot#0 of DE#00 is in Fault status. A disk is not 
actually disconnected when a test Trap is notified.
Sense code
Description
Remarks
SK
ASC
ASCQ
02
04
00
The device is in Not Ready status.
This sense code is notified when the 
relevant event occurs.
04
F1
01
CM is disconnected.
These sense codes are notified when 
"Module was broken" is enabled for 
Error Severity Level in the event 
notification setting.
They are not notified during 
maintenance operations.
04
F1
1A
SFP is disconnected.
04
F1
80
3.5 inch Disk is disconnected.
These sense codes are notified when 
"Disk was broken" is enabled for Error 
Severity Level in the event notification 
setting.
They are not notified during 
maintenance operations.
04
F1
81
2.5 inch Disk is disconnected.
04
F1
88
Disk is disconnected because an error occurred during 
the Write check of the disk patrol.
These sense codes are notified when 
the relevant event is detected during 
Disk Patrol.