ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
80
Copyright 2012 FUJITSU LIMITED
P3AM-5512-03ENZ0
Chapter 7
Troubleshooting
This chapter explains troubleshooting when errors occur.
If you notice anything unusual during operation, then refer to 
 to check 
the ETERNUS DX Disk storage system status, prepare the necessary information with 
, and contact your maintenance engineer.
7.1
Check List
When the ETERNUS DX Disk storage system is turned off
Check the following points: If none of these resolve the problem, leave the ETERNUS DX Disk 
storage system alone and contact your maintenance engineer.
Is the ETERNUS DX Disk storage system's power cord disconnected?
Is main line switch of power distribution unit (MAIN LINE SWITCH) turned to OFF (O)?
Has the server been turned off?
If the ETERNUS DX Disk storage system power is in conjunction with the power synchronized 
unit, the power of the ETERNUS DX Disk storage system will turn off when the server is 
turned off.
Is there a power failure?
Has there been a recent main power failure?
If the ETERNUS DX Disk storage system is in AC automatic power mode (i.e. AUTO POWER 
switch is turned to ON), the ETERNUS DX Disk storage system turns on automatically after 
the power is restored.