Fujitsu DX60 Manual Do Utilizador

Página de 122
Appendix A  Event Notification Message List
  A.2  Message List
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
94
Copyright 2012 FUJITSU LIMITED
P3AM-5512-03ENZ0
A.2.2
Error Messages
This section describes the messages that are sent when the severity is Error for each type of 
event.
Error message list
When the event type is "P"
The following messages are sent when components fail or degrade or when a temperature 
error is detected.
Event type 
and event 
code
SNMP Trap
Upper: Message
Remarks
Trap 
No.
TrapItemID
Trap
Sensor
Info
Lower: Description
P 01SSMM00 2
0100MM00
-
Controller Module#m(zz xxHz) Fault 
<pppppppppppp ssssssssss rrrrr>
These messages 
are notified when 
"Module was bro-
ken" is enabled for 
Error Severity Level 
in the event notifica-
tion setting.
They are not notified 
during maintenance 
operations.
CM is disconnected.
SS: Component subtype
MM
: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
P 06SSMM00 2
0600MM00
-
Controller Module#m(zz xxHz) BE Expander 
Fault <pppppppppppp ssssssssss rrrrr>
CM EXP is disconnected.
SS: Component subtype
MM
: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
P 08SSMM02
0800MM0p
-
Controller Module#m(zz xxHz) DI Port#p Fault 
<pppppppppppp ssssssssss rrrrr>
CM DI Port is disconnected.
SS: Component subtype
MM
: CM module ID (10 – 11)
p: Port number (0 – 1)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version