Exhaust fumes smelled 
in room, headaches.
-  check all seals.
 Fireplace is spilling.
Carbon is being de-
posited on glass, logs 
or combustion cham-
ber surfaces.
Flame is impinging on the logs 
or combustion chamber.
-  check that the logs are correctly positioned.
-  open air shutter to increase the primary air.
-  check the input rate: check the manifold pressure and orifi ce 
size as specifi ed by the rating plate values.
- check that the door gasketing is not broken or missing and that 
the seal is tight.
- check that both vent liners are free of holes and well sealed at 
all joints.
A i r   s h u t t e r   h a s   b e c o m e 
blocked
-  ensure air shutter opening is free of lint or other obstructions.
W h i t e   /   g r e y   f i l m 
forms.
Sulphur from fuel is being de-
posited on glass, logs or com-
bustion chamber surfaces.
-  clean the glass with a recommended gas fi replace  glass 
cleaner. DO NOT CLEAN GLASS WHEN HOT. 
If deposits are not cleaned off regularly, the glass may become 
permanently marked.
Main burner goes out; 
pilot goes out.
REFER TO "MAIN BURNER GOES OUT; PILOT STAYS ON"
Thermocouple shorting or 
faulty.
Vent re-circulating 
-  check joint seals and installation.
- loosen and tighten thermocouple
-  clean thermocouple and valve connection.
-  replace thermocouple.
-  replace valve.
Vent is reversing 
-  check all venting and insert seals. 
-  check that door is properly sealed. If the insert is allowed to burn 
with the door off when purging the unit, exhaust products may 
escape through the air intake pipe and reverse the venting action. 
Let the unit cool down to correct the reversed venting action.
Main burner fl ame is a 
blue, lazy, transparent 
fl ame.
Blockage in vent.
-  remove blockage. In really cold conditions, ice buildup may 
occur on the terminal and should be removed as required.
-  vent liners are reversed. Refer to Figure 2.
-  check all venting and insert seals.
Incorrect installation.
SYMPTOM
PROBLEM
TEST SOLUTION