Friedrich US12D10 Brochura
WINDOW AIR CONDITIONER SELECTOR GUIDE
COMMERCIAL GRADE
RESIDENTIAL GRADE
Kühl
®
Kühl
®
+
Chill
™
Chill
™
+
O
VERVIEW
Description
Bold design and
exclusive features.
Programmability to rival
central systems. Trusted
Friedrich durability.
Designer colors.
All the performance and
durability of Kühl, plus
heating. Choose efficient
heat pump or toasty
electric heat.
Good value. Available
in a large range of
cooling capacities.
24-hr. timer.
Good value. Four
models with electric
heat. 24-hr. timer.
Room size (sq. ft.)
100-2700
350-2700
100-1500
100-1500
Functions
COOL
HEAT/COOL
COOL
HEAT/COOL
Applications
COMMERCIAL AND
RESIDENTIAL
COMMERCIAL AND
RESIDENTIAL
RESIDENTIAL AND LIGHT
COMMERCIAL
RESIDENTIAL AND LIGHT
COMMERCIAL
COMF
ORT & CONVENIENCE
Electronic controls
Y
Y
Y
Y
Timer
7-day with up to 4
settings per day*;
24 hr. timer
7-day with up to 4
settings per day*;
24-hr. timer
24 hr.
24-hr.
Remote control
LCD
LCD
LCD
LCD
Control with smart phone or computer with
FriedrichLink
™
(accessory required)
Y
Y
—
—
Auto-restart w/setting retention
Y
Y
Y
Y
Auto temp/ fan speed adjustment
Y
Y
—
—
Comfortwatch™ technology
Y
Y
—
—
Air flow directions
8
8
4
4
Auto swing louvers
—
—
All except CP05
Y
Optional color fronts
Y
Y
—
—
SOUND REDUC
TION
TECHNOL
OG
Y
Steel inner wall and extra dense insulation
Y
Y
—
—
Vibration isolating design and
components
Y
Y
—
—
Superior airflow design
Y
Y
—
—
EARTH FRIENDL
Y
ENERGY STAR
®
models
Y
Y
Y
Y
Smart Grid capable
Y
Y
—
—
Environmentally friendly R-410A
Y
Y
Y
Y
Energy saver switch
Y
Y
Y
Y
RoHS compliant
Y
Y
—
—
HEAL
TH
Washable, antimicrobial air filter
Y
Y
Y
Y
Optional carbon filter
Y
Y
—
—
Check filter reminder
Y
Y
—
—
Superior fresh air intake/stale air exhaust
Y
Y
Stale air exhaust only,
all except CP05
Stale air exhaust only
SAFETY
EntryGard™ anti-intrustion protection
Y
Y
Y
Y
Insect barrier
Y
Y
—
—
INST
ALLA
TION
Slideout chassis
Y
Y
All except CP05
Y
Power cord direction
Left or right
Left or right
Left or right
Left or right
Thru-the-wall installation option
Y
Y
All except CP05
Y
Window installation hardware
Heavy duty
Heavy duty,
available as accessory
Standard
Standard
Product Selection Tools
COOLING SIZING GUIDE
Area to be conditioned in
sq. ft.
Cooling Btu
100 - 150
5000
150 - 250
6000
250 - 300
7000
300 - 350
8000
350 - 400
9000
400 - 450
10000
450 - 550
12000
550 - 700
14000
700 - 1000
18000
1000 - 1200
21000
1200 - 1400
23000
1400 - 1600
25000
1600 - 1900
28000
1900 - 2700
36000
These tools are only a guide. Due to variations in room design, local climate
and occupancy, larger areas may require the use of multiple units to provide
the optimal cooling solution. Please consult your local authorized Friedrich
distributor or the Friedrich Technical Assistance team for sizing or
application assistance.
COOLING SIZING GUIDE
The cooling guide to the right is based on normal room insulation, average
number of sun-exposed windows and two-person occupancy.
HEATING SIZING INFORMATION
In heating mode, an energy efficient heat pump will generate slightly less
heating Btus than it would in cooling mode. However, in heating mode, heat
pumps use approximately 1/3 the energy of resistance heat, making them an
excellent high efficiency alternative. Back-up resistance heat ensures heat
operation below 40� F outdoor temperatures for year ‘round comfort.
and occupancy, larger areas may require the use of multiple units to provide
the optimal cooling solution. Please consult your local authorized Friedrich
distributor or the Friedrich Technical Assistance team for sizing or
application assistance.
COOLING SIZING GUIDE
The cooling guide to the right is based on normal room insulation, average
number of sun-exposed windows and two-person occupancy.
HEATING SIZING INFORMATION
In heating mode, an energy efficient heat pump will generate slightly less
heating Btus than it would in cooling mode. However, in heating mode, heat
pumps use approximately 1/3 the energy of resistance heat, making them an
excellent high efficiency alternative. Back-up resistance heat ensures heat
operation below 40� F outdoor temperatures for year ‘round comfort.
Common Window Types
Single/double hung
Slider
(Opens up or down)
(Opens left to right, or right to left)
Awning Hopper
Casement
(Cranks out)
(Opens in)
(Cranks out)
Traditional wooden windows are typical in many residences built before
1965, but more modern windows are often constructed of aluminum or vinyl.
Many newer energy efficient windows like double-glazed windows actually
sandwich low conductance gas between two panes of glass. While Friedrich air
conditioners may be used with this type of window, care should be taken not to
break the seal between the two panes of glass during installation.
Depending on the style of window in the application, you may want to consider
the cooling solutions in the adjacent chart. Professional installers may be able
to make field adaptations, including removing all or part of a window to support
alternative types of air conditioning units. Professional installers should also be
able to tell you about any local codes that may apply to your installation.
THRU-THE-WALL INSTALLATION
Many models may be installed through a wall so long as the unit’s side vents are
not blocked or covered in any way. See page 15, In-wall Installation max. depth.
1965, but more modern windows are often constructed of aluminum or vinyl.
Many newer energy efficient windows like double-glazed windows actually
sandwich low conductance gas between two panes of glass. While Friedrich air
conditioners may be used with this type of window, care should be taken not to
break the seal between the two panes of glass during installation.
Depending on the style of window in the application, you may want to consider
the cooling solutions in the adjacent chart. Professional installers may be able
to make field adaptations, including removing all or part of a window to support
alternative types of air conditioning units. Professional installers should also be
able to tell you about any local codes that may apply to your installation.
THRU-THE-WALL INSTALLATION
Many models may be installed through a wall so long as the unit’s side vents are
not blocked or covered in any way. See page 15, In-wall Installation max. depth.
Cooling Solutions
WHICH AIR CONDITIONER
IS RIGHT FOR YOU?
Window Type
Air Conditioner
Single/double hung
Window, portable,
ductless
Slider
Window, portable,
ductless
Casement
Window, portable,
ductless
Vertical Casement
Window, portable,
ductless
Awning
Window, portable,
ductless
Hopper
Window, portable,
ductless
Picture (non-opening)
Thru-the-wall,
ductless
*Requires internet connection
4
5